8. Operation instructions
1. AC/DC voltage measurement
• Select AC voltage or DC voltage gear
• Insert red meter test lead into red jack (positive terminal), black
meter test lead into black jack (COM terminal)
• Touch the test piece by red and black meter test lead, for
example, power socket (Figure 3).
• Read measurement value from LCD screen .
When measure voltage, maximum input voltage is 600V (AC/DC),
do not exceed this limitation, otherwise it may cause electric shock
or damage to the meter.
figure 3.
2. Resistance/circuit on-off/diode/capacitance
• Insert red meter test lead into red jack (positive terminal), black
meter test leads into black jack (COM terminal)
• Connect meter pen in parallel to test piece for measurement
(Figure 4)
• Read measurement value from LCD screen.
When measure resistance/on-off/capacitance/diode range, do
not input voltage over DC 60V or AC 30V to avoid damage.
figure 4.
9