Major tech MT975 Manuale di istruzioni - Pagina 3

Sfoglia online o scarica il pdf Manuale di istruzioni per Strumenti di misura Major tech MT975. Major tech MT975 16. Sound level meter

Under range display
A & C Weighting
FAST & SLOW response
Analog AC/DC outputs for connection to frequency
analyzer or X-Y shaft recorder

3. SPECIFICATION

Standard applied: IEC61672 -1 CLASS2
Accuracy:±1.4dB
Frequency range:31.5HZ ~ 8KHZ
Dynamic range:50dB
Memory:32700
Level ranges: LO:30dB~80dB
Med:50dB~100dB
Hi:80dB~130dB
Auto:30dB~130dB
Frequency weighting: A/C
Time weighting: FAST ( 125ms ), SLOW ( 1s )
Microphone: 1/2 inch electret condenser microphone
Display: 4 digits LCD display with a resolution of 0.1dB
Display Update: 2 times/sec.
MAX hold: Hold the Maximum reading
MIN hold: Hold the Minimum reading
HOLD: Hold the readings
Alarm function: "OVER"is when input is more than upper
Analog output: AC/DC outputs from earphone outlet
limit of range."UNDER"is when input is
less than lower limit of range.
AC=1Vrms ,DC=10mV/dB
3