Major tech MTD73A Manuale di istruzioni - Pagina 13

Sfoglia online o scarica il pdf Manuale di istruzioni per Strumenti di misura Major tech MTD73A. Major tech MTD73A 20. 800a ac true rms digital clamp meter

Major tech MTD73A Manuale di istruzioni
Resistance Measurement
1.
Insert the black test lead into the negative COM
terminal and the red test lead
into the positive V/ terminal.
2.
Set the function switch to the
position.
Use SELECT Button to select 
3.
4.
Touch the test probe tips across
the circuit or component under
test. It is best to disconnect one
side of the device under test so
the rest of the circuit will not
interfere with the resistance reading.
5.
For Resistance tests, read the resistance on the LCD
display.
Capacitance Measurement
WARNING: To avoid electric shock, discharge the capacitor
under test before measuring.
1.
Insert the black test lead into the
negative COM terminal and the
red test lead into the positive
V/ terminal.
2.
Set the function switch to the
position.
3.
Use SELECT Button to select
4.
Touch the test probe tips across the circuit or
component under test. It is best to disconnect one
side of the device under test so the rest of the circuit
will not interfere with the resistance reading.
5.
Capacitance value displayed on the LCD display.
nF