11. Door Height 
 
Function 
Adjusts the open direction slow stopping point to cater for 
high doors 
 
 
12. Door Travel Adjustment
Important Note ‐ When adjusting limits always ensure that the Opener is disengaged from the door and not connected to 
the power supply 
Open Direction 
 Move the door by hand to the fully open position   
 Remove light cover to expose Limit Cams (Fig. 7‐E & F) 
 Loosen the 3 lock screws so that the Cams turn freely. 
 Rotate the "Open" Cam (Fig.7‐E) in the direction of the 
limit switch until the switch is heard to "click"   
 Once the switch "clicks" continue to rotate the cam a 
further 5 degrees towards the switch 
 Check adjustment by partially raising and lowering the 
door by hand. The switch should "click" approx 50mm 
before the door stoppers reach the track stoppers 
 If necessary adjust the Open Limit Cam accordingly ‐ 
turn the cam towards switch to decrease door travel 
and away from the switch to increase door travel. 
13. Safety Reverse
 
 
 
During a closing movement Auto Reverse ensures that the garage door will stop and reverse (Safety Reverse) when it 
encounters an obstruction thus ensuring the safety of people and property. During an opening movement the garage door 
will stop (Safety Stop) when it encounters an obstruction. The amount of force required to make the garage door Safety 
Reverse/Stop can be adjusted. A low force value ensures maximum safety, but requires a very well sprung and installed 
door in order to avoid ghosting (false safety reversing/stopping). A high force value ensures that even a badly sprung or 
worn door will work without ghosting. The following details the correct force value set up and adjustment procedure.
 
A MODE
   
 
Description 
The most sensitive system best suited for use on new well 
sprung doors ‐ automatically compensates on each and every 
cycle for door wear ageing and seasonal temperature change 
for the lifetime of the door 
Function 
During a closing movement the Opener will Safety Reverse 
upon encountering an obstruction 
During an opening movement the Opener will Safety Stop 
upon encountering and obstruction 
Enabling 
 Switch power off at power outlet 
 Remove the Light Cover 
 Select Dip 1 (Fig.7‐G) to "ON" position 
Learning   
In order to Learn Safety Reverse and Safety Stop values the 
Opener will be required to complete 6 uninterrupted open 
and close cycles. During the learning process the LED (Fig.7‐I) 
will rapid blink. The LED will extinguish once learning is 
complete   
 
SETTINGS AND ADJUSTMENTS
 
 
 
 
 
 
 
Enabling 
 Dip 7 "OFF" – doors up to 2.5meters high 
 Dip 7 "ON" – doors over 2.5 meters high
Close Direction 
 Move the door by hand to the fully closed position 
 Rotate the "Close" Cam (Fig.7‐F) in the direction of the 
limit switch until the switch is heard to "click"   
 Once the switch "clicks" rotate the cam by 5 degrees 
back away from the switch 
 Check adjustment by partially raising and lowering the 
door by hand. The switch should "click" approx 20mm 
before the door reaches the ground 
 If necessary adjust the Close Limit Cam accordingly ‐ 
turn the cam towards switch to decrease door travel 
and away from the switch to increase door travel. 
 Re tighten the 3 lock screws so that the cams are 
secured firmly in place 
 
 
Adjustment 
Rotate the Green "Offset" Adjust Pin (Diag.7‐C) in a clockwise 
direction (towards Max) to increase the force required to 
make the garage door Safety Reverse or Stop and in an anti 
clockwise direction (towards Min) to decrease the force 
required to make the garage door Safety Reverse or Stop. 
Testing Close Direction Force 
Ensure that the garage door is resting firmly against the 
ground. Open the door and place a 40mm thick block of 
wood on the ground under the path of the door. Now close 
the door – if the drive force value is correct the opener will 
stop and reverse direction upon encountering the block of 
wood. If too little or too much force is required to make the 
opener reverse direction – turn the Green "Offset" Adjust Pin 
(7‐C) 5 degrees in the appropriate direction – clockwise 
(towards "MAX") to increase the amount of force and anti 
clockwise (towards "MIN" ) to decrease the amount of force 
and then repeat the test. 
Important Note: During Learning ‐ if the door load is excessive 
Opener will stop and Courtesy Light will double blink 
 