Major tech MT915 Manuale di istruzioni - Pagina 5
Sfoglia online o scarica il pdf Manuale di istruzioni per Multimetro Major tech MT915. Major tech MT915 12. 2-in-1 cable identifier & digital multimeter
Anche per Major tech MT915: Manuale di istruzioni (8 pagine)
3. SPECIFICATIONS & TECHNICAL DATA
3.1. DMM
Function
DC Voltage
AC Voltage
50-60Hz
DC Current
AC Current
Resistance
Function
Max input voltage
Diode Test
Continuity Check
Display
Over range indication
Polarity
Low Battery Indication "BAT" symbol indicates low battery condition.
Input Impedance
AC Response
ACV Bandwidth
Auto Power Off
Fuse
Batteries
Operating Temperature 0°C to 40°C (32°F to 104°F)
Storage Temperature
Weight
Size
Standard
Range
200mV,
2.000V, 20.00V,
200.0V, 600V
2.000V, 20.00V
200.0V, 600V
200.0μA, 2000μA
20.00mA, 200.0mA
200.0μA, 2000μA
20.00mA, 200.0mA
200.0Ω
2.000kΩ, 20.00kΩ
200.0kΩ
2.000MΩ
20.00MΩ
Range
600V AC/DC
Test current 1mA max., open circuit voltage of
1.5V typical
Audible signal if the resistance is <150Ω
2000 count 3 -1/2 digit LCD
LCD displays "OL"
Minus (-) sign for negative polarity.
>7.5MΩ (VDC & VAC)
Average responding
50Hz to 60Hz
15 minutes (approximately)
mA, μA ranges; 0.2A/250V fast acting Fuse
9V battery and two "AAA" batteries
-10°C to 50°C (14°F to 122°F)
308g
162 x 74.5 x 44.0mm
IEC61010-1 CAT III-600V Pollution degree II,
CE Approved
Accuracy
±(0.5% rdg + 3d)
±(1.0% rdg + 3d)
±(1.0% rdg + 3d)
±(1.0% rdg + 5d)
±(1.5% rdg + 10d)
±(1.5% rdg + 3d)
±(2.0% rdg + 3d)
±(1.8% rdg + 8d)
±(2.5% rdg + 8d)
±(0.8% rdg + 5d)
±(1.2% rdg + 3d)
±(2.0% rdg + 5d)
±(5.0% rdg + 8d)