connected to the housing would be connected to some metal part lf the
tool (e.g. chuck, blade).
Note: The switch of the device must be in the "ON" position and the
main power should be disconnected.
MOTORS
AC-Disconnect the motor from the line by disconnecting the wires at the
motor terminals or by opening the main switch. If the main switch is used
and the motor also has a starter then the starter must be held, by some
means, in the "ON" position. In the latter case, the measured resistance
will include the resistance of the motor, wire and all other components
between the motor and the main switch. If a problem is indicated, the
motor and other components should be checked individually. If the motor
is disconnected at the motor terminals, connect one megohmmeter lead
to the grounded motor housing and the other lead to one of the motor
leads. DC-Disconnect the motor from the line. To test the brush rigging,
field coils and armature connect one megohmmeter lead to the grounded
motor housing and the other lead to the brush on the commutator. If the
resistance measurement indicates a problem, raise the brushes off the
commutator and separately test the armature, field coils and brush
rigging by connecting one megohmmeter lead to each of them
individually, leaving the other connected to the grounded motor housing.
The above also applies to DC Generators.