Major tech MT570 Manuale di istruzioni - Pagina 9
Sfoglia online o scarica il pdf Manuale di istruzioni per Apparecchiature di prova Major tech MT570. Major tech MT570 16. 5kv high voltage insulation tester
7. Measuring procedure
This insulation tester provides five main functions and four minor
functions:
Main Functions:
1. 500V voltage insulation resistance test.
2. 1000V voltage insulation resistance test.
3. 2500V voltage insulation resistance test.
4. 5000V voltage insulation resistance test.
5. AC/DC voltage measurement.
Minor functions:
Function 1 ─ Date/time adjustment
Function 2 ─ Measurement time setting.
Function 3 ─ Display data stored
Function 4 ─ Delete data stored
7.1. Insulation resistance measurement test (main function)
Note:
1. Before test performed, be sure that no voltage is present. If
voltage is present, disconnect the power supplied.
2. To secure operator's safety, check if there is any damage on the
insulation tester or test cable.
3. During the test, do not touch any exposed metal parts or test
lead tip.
4. Wear insulation gloves and rubber shoes while operating this
high-voltage measuring instrument.
7.1.1. Checks before test is performed:
Turn the function rotary switch to any functions to check if the
Battery power is enough or not.
If the Battery power is approximate DC 10V, "Batt. Low" will be
displayed on the LCD display.
If the Battery power is approximate DC 8.5V, "Batt. Fail" will be
displayed on the LCD display. Then, please replace with new
Alkaline batteries.
9