Brief Introduction
G100-XXN is a main member of digital-chargers from Green Digital
Power-tech Co., Ltd. It represents today's new technology for 24V(20s) ~
36V(30s) NIMH/NICD battery pack charging. G100-XXN programmed 3 auto
stages ( Ip-Im-It) charging process,It is designed for 20s(24V) ~ 30s(36V)
4~25Ah NIMH/NICD battery pack. Stage "Ip" is a pre-charge function for
deep discharged battery pack, this is helpful for battery's cycle life. When the
battery recovered by pre-charge small current, stage "Im" will give bulk current
charging. This is the main charge stage, when the battery nearly charged full ,
-dV phenomenon will be detected by the MCU in charger (-dV value is
3~6mV/per cell about) . Then the battery will leave bulk stage and cut-off
output or enter a defined trickle pulse charge stage "It" to maintain battery.
Further, G100 can display the charging process, indicate the battery
capacity from 25% to 100% timely. This is helpful for user.
For more safety, G100 will inter protection mode when the battery polarity
reversed our the output connectors shorted.
Specification for G100-XXN
Input Voltage
100-240VAC,50-60Hz
Input Current
1.6A
Back current drain
<1mA
Charge voltage limit
G100-24N
32V+-1%
Bulk charge current
2.8A+-5%
-dV>=5mV/cell or
Cutoff condition
battery pack>=50℃ or Timer out or Peak-voltage trigger
Operate Temperature
-20℃~50℃
Natural convection. Do not cover the charger.
Cooling
Charge principle
Auto 3 stages: Ip-Im-It
Battery type
NIMH/NICD 24V~36V(20S~30S)
Battery capacity
3-25Ah
Size
170X70X51mm
Dust protected, Water splashing resistance)
Enclosure
IP54 (
Weight
400g
G100-36N
48V+-1%
1.8A+-5%
dT/dt>=0.6 ℃ /per minute or Temperature of
Display Panel
Power on
(When
AC
input OK)
Charging process indicator:
Indicate battery capacity from 25% to 100% when
charging.
All lamps flashing means battery polarity reversed or
output shorted.
All lamps are "off" means no battery.
How to use:
Connect the AC cord to the socket, The "power" lamp will light on solid.
1.
Connect positive charger clip (red) to positive battery terminal, the black clip
2.
to negative. (You can use other dc plugs to connect battery), the
"25%~100%" lamps will light on flowing. If the battery polarity reversed or
output shorted, all lamps will flashing, please check the setup.
Depend on the charged capacity, 25%~100% lamps will lights up solid
3.
sequence, until the battery is fully charged. Then you can power off the
charger and disconnect the battery or you can charge a new battery if you
need.
The table shows the duration of 95% state charged for an empty battery.
Battery Cap.(Ah)
G100-24N hours
3.6
8.0
13.0
22.0
G100-36NS hours
1.5
2.5
3
5
5
8
8.5
13