PARAMETER 9 AND 10:
Programmable values:
Any day, from 00.00 to 23:59
Default value:
From SATURDAY at 12.00 to SUNDAY at 22.00
NOTE:
These parameters set a time window during the week in which the charger is allowed to fully charge and Equalize
the battery. It's recommended to set a minimum Equalize time of 12 hours after the normal completion of the charge cycle.
PARAMETER 11:
WBM ENABLE
Programmable values:
Enabled, Disabled, Optional
Default value:
Disabled
NOTE:
This parameter sets the operation of the charger with the Wireless Battery Identification module WBM (optional).
Three different operating modes are selectable.
Enabled:
When a battery is connected, the charger establishes a communication with the WBM and uses the information
stored into the WBM to optimize the charge cycle.
Only batteries with WBM installed and properly configured will be charged!
Disabled:
The communication of the charger with WBMs is disabled, and any battery (with correct voltage) will be charged.
Optional:
When a battery is connected, the charger tries to establish a communication with the WBM.
If a WBM is found, it's used to optimize the charge cycle and to add the battery ID tag on the charge history log.
If a WBM is not found, the battery will be charged anyway.
PARAMETER 12:
WIRED IP ADDRESS RS-485
Programmable values:
1 to 254
Default value:
1
NOTE:
This parameter sets the IP address of the charger, when it's connected to a wired DoctorFleet.com management
network.
PARAMETER 13:
RESET WIRELESS
Programmable values:
Disabled / Try Search.NET
Default value:
Disabled
NOTE:
This parameter is used during the setup procedure of a wireless DoctorFleet.com management network.
PARAMETER 14:
TEST WIRELESS
Programmable values:
Disabled / Try Send Test.
Default value:
Disabled
NOTE:
This parameter is used during the setup procedure of a wireless DoctorFleet.com management network.