Gantner Q Series Manuale - Pagina 9

Sfoglia online o scarica il pdf Manuale per Strumenti di misura Gantner Q Series. Gantner Q Series 17.

4
4.1
4.2
4.3
9

Prerequisites

Interface to the ARINC 429 avionics data bus

The ARINC429 Specification defines the standard requirements for the
transfer of digital data between avionics systems on commercial aircraft.
ARINC429 is also known as the Mark 33 DITS Specification. Signal levels,
timing and protocol characteristics are defined for ease of design
implementation and data communications on the Mark 33 Digital
Information Transfer System (DITS) bus.
With the ARINC 429 plugin (GInsARINCPlugin) you can connect a Q.series
system to an ARINC 429 avionics data bus. The GInsARINCPlugin is an
extension that adds support for the AIM ASC429-x USB 2.0 SmartCable™ to
the Q.station.
Figure 4-1 AIM ASC429-x USB 2.0 SmartCable™
Input channels from the ARINC 429 data bus can be written to the
Q.station's virtual variables, which allows for recording and sampling
ARINC bus data in conjunction with Q.series measurement data.

About this manual

This manual describes the setup, configuration and operation of the
GInsARINCPlugin using the test.commander and GI.monitor software
programs. The general setup and operation of your system is described in a
separate manual.
You will find this manual also as a PDF file on our website page
www.gantner-instruments.com.

Minimal system requirements

Q.station, Q.raxx station or Q.brixx station
Q.station firmware 2.11 B04 or later
GI.monitor version 1.2 or later
Version no. 1.0
Released February 12, 2018