Device Installation

3.1
Device Wiring
1 Wiring Embedding
Before installing the digital detection module, plan the layout of the power cable.
For the diameter selection for the extension power cable, see the table below.
Diameter Selection for Extension Power Cables
The device is powered by DC 12V/2A and the lower limit of the operating
Wire Diameter
(mm)
Transmission
Distance (m)
2 Wiring description
The figure below shows the wiring between the digital detection module and
different devices. For the wiring terminal of each device, see the operation manual
of the device or consult manufacturers.
Digital
detection
module
voltage is DC 9V (12V–25%).
0.8mm
(20 AWG)
18
VDD12V Red
Power
GND
input
RS485_P Blue
RS485
RS485_N Brown
www.2MTechnology.net