deconta AS 300 CG Manuale di istruzioni - Pagina 12

Sfoglia online o scarica il pdf Manuale di istruzioni per Sistemi di filtrazione dell'acqua deconta AS 300 CG. deconta AS 300 CG 15. Waste water filtration unit

8.1 Daily care

 Check hoses for free flow
 Visual check of 220µ-Pre filter for dirt
 Control of fine filter via manometer

8.2 Filter change

The Bag filter inserted in the coarse pre filter may be removed, cleaned and reused.
The Manometer controls the fine filter. We recommend a filter change at approx. 3bar.
Cap nut
Fine filter 5µ
Pre filter 220µ
Filter head screw
Attention:
 Change Filter only when device is switched off
 Demount dirty filters only in wet shape to avoid contamination
 Use approved filters only
 Do not use damaged filter candles
Instruction manual
AS 300 CG

8 Maintenance and care

Coarse pre filter with
bag filter 220µ
Manometer
Pre filter 1µ
Seite 12