Water Management Boiler System C 110 L 110V

7.4 Cleaning waste water pump

 Remove hoses
Remove fastening screw of pressure switch. ATTENTION: Do not alter the
middle adjusting screw!
 Remove fastening screw of pump head and take off the head
 Remove Valve plate and clean on front and back
Instruction manual
Hose
Fastening screw pump head
Fastening screw pressure switch
Adjusting screw
Hose
Valve plate
Seite 11