IKEA IHW8305WS0 Istruzioni per l'installazione e manuale d'uso e manutenzione - Pagina 9
Sfoglia online o scarica il pdf Istruzioni per l'installazione e manuale d'uso e manutenzione per Cappa di ventilazione IKEA IHW8305WS0. IKEA IHW8305WS0 28. 30"(76.2cm) wall-mount canopy
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect
power.
2. Remove terminal box cover.
3. Remove the knockout.
A
S
...................
A. Knockout
B. Terminal box cover
4. Install the UL listed or CSA approved strain relief.
A. Y2"conduit
B. Terminal box cover
......C
F
C. UL fisted or CSA approved strain relief
D. Green (or bare) wire connected
to yellow-green
wire
E. White wires
F. Black wires
5. Run 3 wires, black, white and green (14 AWG), in Y2"conduit
from service panel to terminal box.
6. Use UL listed wire connectors
and connect black wires
together.
7. Use UL listed wire connectors
and connect white wires
together.
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical
shock.
8. Use UL listed wire connectors
and connect green (or bare)
wire with yellow-green
wire.
9. Replace terminal box cover.
10. Check all light bulbs to make sure they are secure in their
sockets.
11. Reconnect power.
1=
2.
3=
4.
n
nt C
Install vent cover by placing both vent covers on the hood.
Secure lower vent cover to hood with 2 - 2.9 x 6.5 mm
screws, one on either side.
Lift upper vent cover to the ceiling.
Secure upper vent cover to vent cover bracket with 2 - 2.9 x
6.5 mm screws. Do not completely tighten the lower screws,
but leave a clearance of about Hd' (2.0 mm).
A
A. Vent cover
bracket
B. Upper
vent cover
C. Lower
vent cover
D. 2.9 x 6.5 mm screws