Bernee BN-5606H3/M3 series Manuale d'uso - Pagina 9
Sfoglia online o scarica il pdf Manuale d'uso per Fotocamera digitale Bernee BN-5606H3/M3 series. Bernee BN-5606H3/M3 series 11. Integrated speed dome cameras
Step 3: install transparent cap
Video line
Red:
AC24V
Black:
AC24V
Green: RS 485+
Yellow: RS 485-
ERRORS & SOLUTIONS
Errors Descriptions
Powered on, but no
reaction, no image and
no indicator shining
Powered on, self-test
well, having image, but
out of control
Fail to finish self-test,
having image but with
motor hums
Image Unstable
Image Vague
Dome control of stop
failed or delayed
Switch image with
vertical rolling on
monitor
MAINTAIN
1.
Please accord to operating environments.
2. Do not let dome direct to strong light objects.
No matter in working or not working, dome MUST NOT direct to the sun and other objects with strong light.
Otherwise, CCD maybe damaged permanent.
3. Do not install indoor dome in outdoor environments.
4. Electric safety, lightning proof, surge proof
In process of using this products, should accord to each item of electric safety criteria. Dome and signal line must be
at least 50 meters away from high voltage equipments & lines. If it is hard to meet the above requirements, please adopt
steel tube to wrap signal line, besides set some grounding for steel tube;
Outdoor type speed domes can prevent equipments being destroyed by under 0
and other suchlike pulse signals.
5. Transparent cover cleaning
In order to ensure dome image clear, transparent cover should timely cleaned. When cleaning, we should only hold
outer ring of transparent cover, but not directly touch the cover, otherwise acid sweat will erode the cladding material of
glass surface, moreover other rigid substance can also scratch the cover, causing image vague. So you'd better use
soft enough materials (i.e. cloth). As for serious stains, both neutral detergent and other high-quality personal
detergents are suitable.
Possible Reasons
Power line connection incorrect
Power source damaged
Fuse tube broken
Power line contact poor
Dome address & baud-rate setting wrong
Protocol wrong
RS485 line connection inverted or open-circuit
Mechanical errors
Camera slope
Power inadequate
Video circuit contact poor
Power inadequate
Focus by manual
Dome shell dirty
Dome power inadequate
Check whether controlling-resistance of farthest
dome is added
Dome phase is wrong
Bolt one end of safety rope of transparent cover
to the screw bolt of outer shell. Take off 2 screws of
outer shell edge. Closely connect fixing hole of
transparent cover with screw hole of outer shell,
confirm matched holes directing to each other
exactly and transparent cover has been attached on
outer shell. Finally put and fasten 2 steel screws in
order to fix transparent cover.
Cautions: ahead of transparent-cover-cap covered
down, must connect well the power socket of
heater.
Solutions
Revise
Replace
Replace
Remove poor contact
Reset dome address code & baud rate
Revise
Check connection of RS485 control line
Examine & repair machine
Place well
Replaced with proper power supply, near to camera for better
Remove poor contact
Replace
Operate dome or call any preset position
Clean shell
Replaced with proper power supply, near to camera for better
Add proper resistance for farthest dome
If one power line links multiple domes (centralized power
supply). 24V AC connector should be linked with same
direction. Each connector end should connect to 24VAC
connector terminal; so do the other end and terminal
~±
- 7 -
Dome power 1
Dome power 2
Dome power 3
4000W lightning strike, surge