Troubleshooting

Problem
Possible Cause
Fuse blown or circuit breaker tripped.
Power cord unplugged.
Compressor not running.
Thermostat set too high.
Cabinet in defrost cycle.
Excessive amount of warm product
placed in cabinet.
Prolonged door opening or door ajar.
Condensing units run for
long periods of time.
Door gasket(s) not sealing properly.
Dirty condenser coil.
Evaporator coil iced over.
Thermostat set too warm.
Airflow blocked.
Excessive amount of warm product
placed in cabinet.
Cabinet temperature is
Fuse blown or circuit breaker tripped.
too warm.
Dirty condenser coil.
Evaporator coil iced over.
Low refrigerant levels.
Door is slightly ajar.
Condensation is
Gasket is not sealing properly.
collecting on the cabinet
Relative humidity is above 60%.
and/or floor.
Poor switch connection.
Interior light is not
Bulb is not connected.
working.
Bulb has burned out.
www.AvantcoRefrigeration.com
8
User Manual
Reach-In Refrigerators & Freezers
Possible Solution
Replace fuse or reset circuit breaker.
Plug in power cord.
Set thermostat to lower temperature.
Wait for defrost cycle to finish.
Allow adequate time for product to cool down.
Ensure doors are closed when not in use. Avoid opening doors for
long periods of time.
Ensure gaskets are snapped in completely. Remove gasket and
wash with soap and water. Check condition of gasket and replace if
necessary.
Clean the condenser coil. (Page 7)
Unplug unit and allow coil to defrost. Make sure thermostat is not
set too cold. Ensure that door gasket(s) are sealing properly.
Set thermostat to lower temperature.
Re-arrange product to allow for proper air flow. Make sure there is
at least four inches of clearance from evaporator.
Allow adequate time for product to cool down.
Replace fuse or reset circuit breaker.
Clean the condenser coil. (Page 7)
Ensure doors are closed when not in use. Avoid opening doors for
long periods of time.
Contact a service technician to check refrigerant levels.
Make sure door is completely closed.
Clean, repair, or replace the gasket as necessary.
Move unit to area below relative humidity or lower humidity level.
Turn off light switch and turn it back on.
Make sure the bulb is correctly inserted in the socket.
Replace the bulb.