Installing the dome enclosure
1. Remove the dome cover and the camera linear
Gently turn the dome cover counter-clockwise to unlock and pull free of the dome base. Remove the
camera linear by gently pulling it free of the two notches (D4) in the camera base (see fig. D)
2. Use the template to mark and prepare the mounting area
This installation sheet is designed to maintain the IP and NEMA rating independent of the chosen
installation method. Therefore, all mounting access positions are sealed until they are ready to be
used. When mounting the dome to a ceiling or wall using screws, use the template to cut a hole as
the circle marked"T5" with a hole cutter.
3. Open the required knock-out panel
Use a sharp knife or side cutter pliers to cut one of the side knock-outs (C3) to the size required to
allow cable insertion. Be careful not to hurt yourself or damage the camera when using knives and
side cutter pliers.
4. Mount the dome enclosure
Using one of the mounting schemes discussed overleaf (Methods for mounting the enclosure), fix
the dome enclosure in place.
5. Connect the connecters
All wires have been connected to the circuit board sealed
on the dome base.
When the enclosure is mounted
securely to a surface, connect your video out and power
in the cables to the G1 and G2 connectors.
A service jack socket is also provided for temporary video
connection when focusing the camera, using an optional
Service jack socket.
Important: Use only a Class 2 certified power supply.
6. Adjust the camera position
You can adjust the focusing position by rotating and
panning the camera base (see fig. E)
7. Install the camera liner
Carefully fit the camera linear (F1) over the camera base so that it snaps into place as shown in fig F
and does not obstructed the camera lens.
8. Replace the dome cover
Replace the dome cover (F2) and rotate to close it as shown in fig.F. Use the supplied T2 screw to
secure the whole enclosure (see fig. G)
9. Install the Quick Mount Kit (optional) (see fig.H)
a. Use the screws to adjust the position of the two locking arms on the Quick Mount adapter.
b. Thread cables through the Quick Mount adapter (H1) and install it onto the dome enclosure.
c. Attach Camera to Quick Mount Install Adapter using the thread.