Electrical requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions
can result in death, fire, or electrical
shock.
If codes permit and a separate ground
wire is used, it is recommended that
a qualified electrician determine that
the ground path is adequate.
Do Not ground to a gas pipe.
Check with a qualified electrician if
you are not sure the dishwasher is
properly grounded.
Do Not have a fuse in the neutral or
ground circuit.
A 120-volt, 60-Hz, AC-only, 15- or
20-ampere fused electrical supply is
required. (Circuit breaker or time-
delay fuse is recommended.) It is
recommended that a separate circuit
serving only this appliance be
provided.
Hot Water Accessory Tank
If you plan to install the Hot Water
Accessory Tank Part No. 4396282, an
additional separate120-volt, 60-Hz, AC-
only, 15 or 20-ampere fused electrical
supply is required.
Garbage Disposer
If you plan to install garbage disposer,
an additional separate 120-volt, 60-Hz,
AC-only, 15 or 20-ampere fused
electrical supply is required.
4
Recommended
ground method
For your personal safety, this
appliance must be grounded. This
appliance is equipped with a power
supply cord having 3-prong ground
plug. To minimize possible shock
hazard, the cord must be plugged into
a mating 3-prong ground-type outlet,
grounded in accordance with local
codes and ordinances. See Figure 1.
If a mating outlet is not available, it is
the personal responsibility and
obligation of the customer to have a
properly grounded 3-prong outlet
installed by a qualified electrician.
3-prong
ground-type
3-prong
outlet
ground
plug
ground
prong
power
Figure 1
supply
cord
If dishwasher must
be direct wired
• Use flexible, armored or non-
metallic sheathed, copper wire with
grounding wire that meets the
wiring requirements for your home
and local codes and ordinances.
• Use a U.L.-listed conduit connector
or if using non-metallic sheathed,
copper wire, a U.L.-listed cable
clamp connector.
Water
requirements
For dishwasher:
• Hot water line with 20-120 psi water
pressure.
120°F water at dishwasher.
• Copper tubing with compression
fitting. 3/8" O.D. is recommended .
• A 90° elbow with 3/8" N.P.T. external
pipe threads on one end.
Important: Do not solder within 6"
from water inlet valve.
For sink faucet:
• Hot and cold water line.
• Copper tubing with compression
fittings for specific faucet to be
installed.
Drain
requirements
Separate drain P-traps for the sink and
dishwasher must be provided.
22-1/32"
to bottom of
dishwasher
drain
1/2"
minimum
Dishwasher drain:
If the dishwasher drain exits through
the back wall, the centerline of the
drain MUST be a minimum of 1/2"
below the dishwasher drain. This is
required to completely drain the
dishwasher tub so that no standing
water remains in tub.
back
wall