1" minimum
side
clearance
from
Discharge
combustible
Nozzle
material*
20˚
6' minimum
EXTERIOR
*Electrically Heated Units Only
For more information see page 4
3
NOTE: Mount large hole
of keyhole slots on top
Ships fully assembled with a mounting plate
For more information see page 5
5
Use threaded rod
to hang from the
ceiling instead of
the wall - using
the factory
installed
threaded inserts.
For more information see page 5
4" minimum*
AIR
Before hanging,
check to see what
the clearance is
above the door.
INTERIOR
Berner International
www.berner.com
111 Progress Ave. / New Castle / PA / 16101 / USA
Architectural Elite 8
Simple to Install
Easy to operate & maintain
2
Rule of thumb –
If the unit must be mounted
higher than 1" above the
opening, it must be spaced out
from the wall 3/8" for every
inch the unit is above
the door opening.
NOTE: The wall plate for this unit is 1.125"
thick which allows a 4" above door mount
before it needs spaced out from the wall.
For more information see page 5
4
After hanging the mounting
plate, drop the air curtain
into place.
For more information see page 5
6
For more information see page 6
800.245.4455
- 3 -
WALL MOUNTING PLATE
AIR CURTAIN
DISCHARGE
GRILL
AIR CURTAIN
DISCHARGE
GRILL
FLUSH FIT
FLUSH FIT