Avantco 178CBE60HC Manuale d'uso - Pagina 11
Sfoglia online o scarica il pdf Manuale d'uso per Attrezzature per alimenti commerciali Avantco 178CBE60HC. Avantco 178CBE60HC 12. Refrigerated chef bases
Anche per Avantco 178CBE60HC: Manuale d'uso (13 pagine)
Condensor Coil Cleaning Instructions
The condenser coil is located at the bottom behind the panel.
A dusty condenser may lead to high energy consumption, less cooling effectiveness, and
compressor damage.
1.
Disconnect the electrical power from the unit.
2.
Remove the front cover and base cover with a screwdriver.
3.
Using a soft brush and/or vacuum, remove the dirt, lint, etc. from the finned condenser coil in a vertical
direction.
4.
Clean the condenser with a commercial condenser coil cleaner, available from any kitchen equipment
retailer. Ex. Nobel Chemical Tech Line
5.
After cleaning, straighten any bent condenser fins with a fin comb.
6.
When finished, be sure to reinstall the front cover and base cover.
7.
Reconnect the electrical power to the unit.
User Manual
Refrigerated Chef Bases
www.AvantcoRefrigeration.com
11