Avantco 178Z1FHC Manuale di servizio - Pagina 5

Sfoglia online o scarica il pdf Manuale di servizio per Attrezzature per alimenti commerciali Avantco 178Z1FHC. Avantco 178Z1FHC 18. Commercial top mount reach-in freezer, solid door
Anche per Avantco 178Z1FHC: Manuale d'uso (9 pagine)

Avantco 178Z1FHC Manuale di servizio

Part Testing

Controller Testing

(Fig. 1)
- Check for 120 volts between black (L) and white (N)
wires, main power, orange terminal connector.
- Check for 120 volts between red (compressor) and
white (N) wires, compressor ON only.
- Check for 120 volts between yellow (fan) and white
(N) wires, fan ON only.

Evaporator Fan Motor Testing

Ensure controller is calling for evaporator fan to run
(Fig. 2) and door switch is closed then:
- Check for 120 volts between yellow (fan) and white
(N) wires, fan ON only.
- Check for 0.5 amps+/- 10% at yellow wire at rear of
controller.
If tests above fail, replace fan motor.

Condenser Fan Motor Testing

Ensure controller is calling for compressor to run
then: (Fig. 3)
- Check for 120 volts at fan plug between the wires.
- Check for 0.5 amps +/- 10% on red wire.
If tests above fail, replace fan motor.
Temperature Probes, Evaporator,
Cabinet, and Condenser
Test probe while it is in ice water as temperature
effects ohm reading: 26 kiloohms (kΩ) +/-10% = good.
If tests above fails, replace probe.
Service Manual
Fig. 1
Fig. 2
Fig. 3
P. 5