Avantco 178Z2FWMS Manuale di servizio - Pagina 13

Sfoglia online o scarica il pdf Manuale di servizio per Attrezzature per alimenti commerciali Avantco 178Z2FWMS. Avantco 178Z2FWMS 18. Commercial top mount reach-in freezer, solid door
Anche per Avantco 178Z2FWMS: Manuale d'uso (9 pagine)

Avantco 178Z2FWMS Manuale di servizio

Condenser Parts

1. Ensure unit is turned off and unplugged.
2. Remove the screws holding the front condenser
cover in place. Open front door(s) to access
them and use a 7mm socket. Flip up the cover, if
needed to access the condenser tray parts.
(Fig. 19 & 20)
3. Gain access to the top front of the unit.

Condenser coil

All EPA, federal and local guidelines need to be
followed when working with refrigeration. Follow
all guidelines and safety procedures when working
with a flammable refrigerant. All connections where
refrigerant travels must be checked for leaks after
connections a brazed in place.
4. Remove condenser temperature probe from
condenser line. (Fig. 21)
5. Remove copper lines from condenser coil. (Fig. 21)
6. Remove Phillips screws holding condenser coil to
condenser tray. (Fig. 22)
7. Remove Phillips screws holding condenser fan
cover to condenser coil. (Fig. 23)

Condenser Fan Blade

8. Remove Phillips screw holding fan blade to fan
motor. Note the blade dish and direction for
installation.

Condenser Fan Motor

9. Remove Phillips screws holding fan motor to fan
cover. (Fig. 24)
10. Disconnect fan motor wiring connection.
Continued on next page
Service Manual
Fig. 19
Fig. 20
Fig. 21
Fig. 23
P. 13
Fig. 22
Fig. 24