In situations where it is not possible to sweep through the stove the installer will have provided alternative
means, such as a soot door. After sweeping the chimney the stove flue outlet and the flue pipe connecting the
stove to the chimney must be cleaned with a flue brush.
Periods of Prolonged Non-Use
If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to
remove ash and unburned fuel residues. To enable a good flow of air through the appliance to reduce
condensation and subsequent damage, leave the air controls fully open.

Safety Notes for your guidance

FIRES CAN BE DANGEROUS – Always use a fireguard in the presence of children, the elderly or the infirm.
DO NOT OVERFIRE – it is possible to fire the stove beyond its design capacity, this could damage the stove,
so watch for signs of overfiring – if any part of the stove starts to glow red, the fire is in an overfire situation
and the controls should be adjusted accordingly. Never leave the stove unattended for long periods without first
adjusting the controls to a safe setting – careful air supply control should be exercised at all times.
Any unauthorised modifications of this appliance will render the guarantee null and void and could be
potentially dangerous. Replacement parts should only be sourced from Green Stove approved dealers
WARNING – FUME EMISSION
Properly installed and operated, this appliance will not emit fumes. Occasional fumes from de-ashing and
refuelling may occur. Persistent fume emission must not be tolerated.
If fume emission does persist, then the following immediate action should be taken: -
1.
Open doors and windows to ventilate room
2.
Let the fire out, or eject and safely dispose of fuel from the appliance.
3.
Check for flue chimney blockage and clean if required.
4.
Do not attempt to re-light the fire until the cause has been identified and corrected.
If necessary, seek professional advice.
Important! – Do not fit an extractor fan in the same room as this appliance.

IN THE EVENT OF A CHIMNEY FIRE

Raise the alarm to let others in the house know.
Call the Fire Brigade
Reduce the appliance-burning rate by closing all air controls.
Move furniture and rugs away from the fireplace and remove any nearby ornaments.
Place a fireguard or spark guard in front of the stove.
Feel the chimneybreast for sign of excessive heat.
If the wall is becoming hot, move the furniture away. Ensure that the Fire Brigade can gain access to your roof
space in order to check this area for signs of fire spread.