Installation of Casters:
Cut the two straps which attach the unit to the pallet.
Adjust the unit on the pallet until the pre-drilled holes are exposed.
Using wedges or team-lift, lift the unit high enough that there is enough clearance to affix
the caster.
CAUTION! NEVER LAY UNIT ON ITS BACK! UNIT SHOULD ONLY BE PLUGGED IN WHEN IT
HAS RESTED IN THE CORRECT UPRIGHT POSITION FOR AT LEAST 24 HOURS. Failure to
meet the requirement will void warranty coverage if compressor damage ensues.
For leveling, if dealing with a sloped or uneven floor, shims are provided. Insert any
necessary shims between the caster and the frame rail. Make sure the slot of the shim is
in contact with the treaded stem of the caster. If using more than one shim, it is necessary
to place them in opposite directions. If multiple shims are placed side by side in the same
direction, they may dislodge.
Turn the bearing race clockwise to tighten and secure the caster. Use provided tool to secure
all casters properly.
Electrical:
Please ensure that the required voltage is being supplied at all times.
The unit should be plugged into a grounded and properly sized electrical outlet with
appropriate over-current protection. Please refer to the electrical requirements on the
unit's nameplate.
The unit should have its own dedicated outlet.
Do not use extension cords.
Ensure the unit is not resting on or against the electrical cord.
If the unit is not in use for a long period of time, please unplug the unit from the outlet.
To avoid shock and fire hazards, do not plug in or unplug the unit with wet hands.
After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so
could cause damage to the compressor.

Adjusting the Temperature:

Your new refrigerator is already factory-set to run at optimum temperatures for food safety
and should require no adjustments.
Refrigerators are set to cycle between a minimum temperature of 33°F and a maximum
temperature of 40°F
Adjusting the temperature changes the minimum temperature your unit will run at. Your unit
will not run constantly at this setting. To change it, follow these instructions: