GAPOSA QCF4 Manuale - Pagina 4

Sfoglia online o scarica il pdf Manuale per Motore GAPOSA QCF4. GAPOSA QCF4 20. Encoding photocells

ENCODING PHOTOCELLS
"QCF4"
Wall-mounted encoding photocells, range of up to 15 mt.
The code for the transmitted signal, which must be set at the
time of installation, minimises the possibility of interference
between devices.
T
:
ECHNICAL DATA
- Max. range
- TX power supply
- RX power supply
- TX absorption
- RX absorption
- Relay contact capacity
- Operating temperature
- Container
- Protection rating
- Container dimensions
Selecting Operating Code " A " and " B " ( Jumper J2 ) :
The photocell has two operating encoding channels "A" and "B",
in this way it is possible to install 2 pairs of the same model
without any interference between them. Code "A" ( J2 pos. 1-2
"factory configuration" ) and code "B" ( J2 pos. 2-3 ), must be
accordingly selected in the same way, at the time of installation,
GB
: 15 metres
: 12-24V AC-DC
: 12-24V AC-DC
: 10 mA Max.
: 25 mA Max.
: 1A max at 30 VDC
: -10 ÷ 55 °C
: Polycarbonate
: IP 54
: 82 x 56 x 25 mm.
- 4 -
on both the transmitting part (QCF4 TX) and the receiving part
(QCF4 RX).
QCF4 D
ESCRIPTION OF THE
Power supply:
The transmitter can be powered with 12 or 24 Volts in either DC
(observing the polarity) or in AC
Connections:
1 – 12/24 Vac-dc
2 – 0V
QCF4 DESCRIPTION OF THE RECEIVER ( RX ):
Power supply:
The receiver can be powered with 12 or 24 Volts in either DC
(observing the polarity) or in AC.
Connections:
1 - 12-24 Vac-Vdc Power Supply
2 - 0 Vac-Vdc Power Supply
3 - NO/NC photocell contact ( J1 selection )
4 - NO/NC photocell contact ( J1 selection )
Selecting the NO/NC Relay Contact ( with Jumper J 1 ) :
With jumper selection J1 it is possible to choose the type of
relay contact as NO (Normally Open) or NC (Normally Closed).
J1 position 1- 2 : NO relay contact.
T
( TX ) :
RANSMITTER