AUTOMATIC CLOSING MODE
The control includes, among its functions, the automatic closing after a
set time.
The automatic closing activates by programming the pause time and by
choosing the "impulse" operating mode (DIP 2 in OFF). When the dead-
man logic is active while closing, the automatic closing is excluded (DIP 2
in ON).
In order to program the pause time it is necessary:
1. To put DIP 5 and 6 in OFF
2. To put DIP 5 in ON. The green LED will switch off and make a short
flash every second.
3. Wait for the pause time you want to program (the time must be greater
than 5 seconds, for a maximum of 4 minutes)
4. After the required time replace the DIP 5 in OFF. If programming is
correct, the green LED will flash quickly and then remains lit.
ADDITIONAL NOTE: The time count for the automatic closing starts
when the opening movement is interrupted by the START/STOP
command or the intervention of the limit switch in opening; the
counting of the pause is notified via a short cut off of the green
LED every 3 seconds.
While in pause, a START/STOP control excludes the automatic
closing; a further START/STOP control closes the door. By pushing
the STOP control the automatic closing is excluded.
The automatic reclosure is excluded (even if programmed) if:
• a safety system intervenes (safety stop, photocell, bar, motor
thermal efficiency etc.)
• the dead-man logic is activated in closing
• a closing movement is interrupted.