GAPOSA QC100 Manuale di istruzioni per l'uso - Pagina 7
Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Unità di controllo GAPOSA QC100. GAPOSA QC100 16. Single-phase control unit
SAFETY DEVICES
The safety of the board are managed via DIP 3 and 4:
SAFETY LOGIC
When an obstacle is detected during the way down the move-
ment is reversed until the opening limit switch; It has no effect
on the way up.
When an obstacle is detected during the way down the opening
movement is inverted for 2 seconds and then it stops. When an
obstacle is detected during the way up the movement is imme-
diately stopped.
TYPE OF SAFETY SELECTION
Security input for normally closed contact.
Security input for optoelectronic bar with digital signal.
To be connected as follows: Mass in terminal 3, + 12V DC in
terminal 9, digital signal in terminal 10.
DIP 3
OFF
ON
DIP 4
OFF
ON