CORNING EDGE8-04U Installazione e collaudo - Pagina 2

Sfoglia online o scarica il pdf Installazione e collaudo per Hardware di rete CORNING EDGE8-04U. CORNING EDGE8-04U 8. Tap module
Anche per CORNING EDGE8-04U: Installazione e collaudo (13 pagine)

CORNING EDGE8-04U Installazione e collaudo
2.

Precautions

2.1

Laser Precautions

WARNING: DO NOT use magnifiers in the presence of laser radiation. Diffused laser light
can cause eye damage if focused with optical instruments. Should accidental eye exposure to
laser light be suspected, arrange for an eye examination immediately.
2.2

Cable Handling Precautions

CAUTION: Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces.
Consult the cable specification sheet for the cable you are installing. Do not bend the cable
more sharply than the minimum recommended bend radius. Do not apply more pulling force
to the cable than specified. Do not crush the cable or allow it to kink. Doing so may cause
damage that can alter the transmission characteristics of the cable; the cable may have to be
replaced.
3.

Tools and Materials

3.1
The following tools and materials are required for this procedure:
Power meters with LC port adapters (2)
LC-LC jumpers (2)
SC-LC jumper for the light source (1)
LC-LC adapter (1)
Light source
MTP to LC harness (1)
LC port cleaner (p/n CLEANER-PORT-LC)
MTP Connector and port cleaning tool (p/n 2104466-01)
4.

Connector and Adapter Cleaning

4.1
Cleaning the LC adapters with an LC port cleaner
before each mating is recommended (Figure 2).
4.2
The use of an MTP Connector and Port
Cleaning Tool to clean MTP connectors and ports
before each mating is recommended (Figure 3).
STANDARD RECOMMENDED PROCEDURE 003-137-AEN | ISSUE 1 | JANUARy 2017 | PAGE 2 OF 8
HPA-0738
HPA-0754
Figure 2
Figure 3