KitchenAid 9752397 Manuale di istruzioni per l'installazione - Pagina 2

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Gamme KitchenAid 9752397. KitchenAid 9752397 7. 30" (76.2 cm) sealed burner gas freestanding and slide-in ranges, with self-cleaning thermal/convection oven

KitchenAid 9752397 Manuale di istruzioni per l'installazione
Before you start...
Cabinet opening dimensions
25" (63.5 cm) countertop
depth (with or without
backsplash)
and 24" (61 cm) base cabinet
depth,
36" (91.4 cm) countertop
height
Your safety and the safely of others is
very important.
We have provided many important safety messages in
this manual and on your appliance. Always read and
obey all safety messages.
0
7
This is the safety alert symbol.
This
symbol
.
alerts you to hazards that can kill or hut-l you
and others. All safety messages will be preceded by the
safety alert symbol and the word "DANGER" or
"WARNING". These words mean:
Freestanding
Range
to countertop
I
30" (76.2 cm) ial
///zff5$$
P-5
P-5
opening
width
opening
width
r
You will be killed or seriously injured if you don't
follow instructions.
3"
1
17.6 cml
You can be killed or seriously injured if you don't
folloZ&uctions.
All safety messages will identify the hazard, tell you
how to reduce the chance of injury, and tell you what
can happen if the instructions are not followed.
of range to side wall or
other combustible
material.
24"
-rl
~'1
#-if51
cm)
j
(15.2,cm)l
Gas line opening
can be
located within
this
shaded area.
Wall receptacle
should
be located
,4 cm) within
the 18" x 10"
(45.7 cm x 25.4 cm)
<
shaded
area.
WARNING: If the information
in
this manual is not followed
exactly, a fire or explosion may
result causing property
damage, personal injury or
death.
- Do Not store or use gasoline
or other flammable vapors
and liquids in the vicinity of
this or any other appliance.
- WHATTO DO IFYOU SMELL
GAS
l
Do Not try to light any
appliance.
l
Do Not touch any electrical
switch; Do Not use any
phone in your building.
l
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas
supplier's instructions.
l
If you cannot reach your
gas supplier, call the fire
department.
- Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
2" (5.1 cm)-
7/E" (2.2 cm)
min. required
.between
cabinet
opening
and
door or hinge
opening.
Slide-in Range
-13"
(33&M
max. upper /
\-
cabinet
depth
4
I
For minimum
18" i45.7 cm)
upper cabinet
30" (76.2 cm) cabinet
clearance
to
to countertop
opening
width
coc;,,m
-
--op,
see
I
'..I
, _ ,
opening
width
4" (10 2 cm) min R
cleara'nce
from doth
111
sides of range to side -
wall or other
'I/
I
combustible
material.
/f
/
I
I
IMPORTANT:
k- /
Rear vent must be
1R"
installed on all
slide-in models for
Gas line opening
should
be located
within
this shaded are
proper ventilation.
See Step 7.
floor gas line opening
if directly
below
regulator
located
within
the 18" x 10"
(45.7 x 25.4 cm)
Countertop
opening
dimensions
that are shown
must be used. Given dimensions
provide required
clearances.
When installing a cooktop under existing cabinets
and the installation
does not meet the minimum
cabinet clearances,
install a range hood above the
cooktop to avoid burn hazards.
Read electrical
and carpentry
instructions.
Proper installation
is your responsibility.
A
qualified technician
must install this range. Make
sure you have everything
necessary for correct
installation.
It is the customer's responsibility
to
make sure that the countertop
has been properly
prepared and that the installation
clearances
specified on the model/serial
rating plate are met.
The model/serial
rating plate is located on the
frame behind the drawer.
Check location
where range will be installed. The
range should be located for convenient
use in the
kitchen. Recessed installations
must provide
complete enclosure of the sides and rear of range.
ALL OPENINGS
IN THE WALL OR FLOOR
WHERE RANGE IS TO BE INSTALLED MUST
BE SEALED.
IMPORTANT:
Some cabinet and building materials
are not designed to withstand the heat produced
by the oven for baking and self-cleaning.
Check
with your builder or cabinet supplier to make sure
that the materials used will not discolor, delaminate
or sustain other damage.
shaded
area.
718" (2.2 cm) min. required
between
e
cabinet
opening
and door or hinge
opening.
It is the customer's
responsibility:
To contact
a qualified
electrical
installer.
To assure that the electrical
installation
is
adequate
and in conformance
with National
Electrical
Code, ANSUNFPA 70 -
latest
edition*,
or CSA Standard
C22.1, Canadian
Electrical
Code, Part 1 -
latest edition**,
and
all local codes and ordinances.
Note: This appliance
is manufactured
for use
with Natural Gas. Conversion
to L.P. Gas can
be made using the kit included
in your
literature
package.
Important:
Observe
all governing
codes and
ordinances.
Earthed/grounded
electrical
outlet is required.
See "Electrical requirements,"
Panel C.
Cabinet
opening
dimensions
that are shown
must be used.
Do Not pinch the power supply
cord between
the range and the wall.
Do Not seal range to side cabinets.
Copies
of the standards
listed may be obtained
from:
*National
Fire Protection
Association
Batterymarch
Park
Quincy, Massachusetts
02269
l
* Canadian
Standard
Association
178 Rexdale
Boulevard
Etobicoke
(Toronto),
Ontario
M9W lR3
Note: The metal chassis of the range MUST be
earthed/grounded
in order for the control panel to
work. If the metal chassis of the range is not
earthed/grounded,
NO keypads will operate. Check
with a qualified electrician if you are not sure the
range is earthed/grounded.
'** Note: 30" (76.2 cm) min. when bottom
of wood or
metal cabinet
is protected
by not less than 114"
(0.64 cm) flame retardant
millboard
covered
with not
less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless
steel, 0.024" (0.6 mm) aluminum
or 0.020"
(0.5 mm) copper.
36" (91.4 cm) min. clearance
between
the top of the
cooking
platform
and the bottom
of an unprotected
wood or metal cabinet.
Panel A