Jandy Infinite WaterColors IWCP50W100 Manuale di installazione e funzionamento - Pagina 10

Sfoglia online o scarica il pdf Manuale di installazione e funzionamento per Controllore Jandy Infinite WaterColors IWCP50W100. Jandy Infinite WaterColors IWCP50W100 12. Led lighting
Anche per Jandy Infinite WaterColors IWCP50W100: Manuale di installazione e funzionamento (12 pagine), Manuale (2 pagine)

Jandy Infinite WaterColors IWCP50W100 Manuale di installazione e funzionamento
ENGLISH

Section 8. Amazon Alexa Light Control

Go to iaqualink.com for more information on controlling your Infinite WaterColors lights through Amazon Alexa.

Section 9. Troubleshooting

Problem
Lights don't turn on
Lights are out of sync
One or more lights are dim, blinking
or not working
Lights are flashing yellow
Different colors from
different lights
Page 10
Jandy
Infinite WaterColors
Pool & Spa LED Lights
®
Possible Cause
Lights are not powered
Lights have failed.
Zones are set differently
Poor connection or improper wire
gauge
Lights are not communicating with
the Infinite WaterColors LED Light
Controller or lights are connected
to a non-compatible controller or
transformer.
Zones are set differently
|
Installation and Operation Manual
Corrective Action
Check the 120VAC power supply into
the transformer, 14VAC output at the
transformer, and ensure the lights
are enabled via the iAquaLink app.
Check or reset the GFCI. Make sure
120 volts has not been used in the
installation. If so, damage is assured
and is not warrantable.
Replace the light or swap the PCBA.
See section 10 for replacement
parts.
Check that lights are in the same
zone or the same light show is
applied to all zones.
Separate each light and
independently wire 14VAC to a
single light only. Repeat this process
for each light. If the junction box is
being used, then check for proper
connection of the light cord. Verify
that the correct wire gauge is being
used between the transformer and
junction box.
Confirm lights are powered by the
Infinite WaterColors LED Light
Controller. If not, then connect and
try again. If they're powered, then
check the RS-485 connection.
Check that lights are in the same
zone, or that all zones are set to the
same color.