KitchenAid KEMS379BBL00 Manuale di istruzioni per l'installazione - Pagina 4

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Forno KitchenAid KEMS379BBL00. KitchenAid KEMS379BBL00 17. 27" (68.6 cm) and 30" (76.2 cm) electric built-in microwave/oven combination

KitchenAid KEMS379BBL00 Manuale di istruzioni per l'installazione
Ifcodes permit and a separate ground w ire isused, i tis
recommended
thataqualified electrical installer determine that
theground p ath andwire gauge areinaccordance
withlocal
codes.
Check w ithaqualified electrical installer ifyouarenotsure the
oven isproperly grounded.
This oven must b econnected toagrounded metal, permanent
wiring system.
Besure thattheelectrical connection andwire size areadequate
andinconformance
withtheNational Electrical Code, ANSI/
NFPA 7 0-latest edition orCSA Standards C22.1-94, Canadian
Electrical Code, Part 1 andC22.2 No. O -M91-1atest
edition, and
alllocal c odes a ndordinances.
Acopy oftheabove c ode standards canbeobtained from:
National Fire Protection Association
1 Batterymarch
Park
Quincy, MA02169-7471
CSA International
8501 East P leasant Valley R oad
Cleveland, OH 44131-5575
Electrical
Connection
To properly install your oven, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
Oven must be connected to the proper electrical voltage,
amperage, and frequency as specified on the model/serial
number rating plate. See the following illustration.
Do not cut the conduit. The length of conduit provided is for
serviceability of the oven.
A UL listed or CSA approved conduit connector must be
provided.
If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the ends of the
flexible conduit leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors
and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's
recommended
procedure. Aluminum/copper
connection must conform with
local codes and industry accepted wiring practices.
For power requirements for models WOC54EC7A, WOC54ECOA,
WOC95ECOA and MMW9730A, refer to the following table.
Voltage
Microwave Oven
Microwave Oven
and Microwave
and Microwave
Oven with Single
Oven with Single
Thermal Oven
Convection Oven
240 VAC
5490W
5520W
208 VAC
4590W
4620W
240 VAC
30.4 A
30.5 A
208 VAC
28.4 A
28.6 A
For power requirements for models KEMS379B and KEMS309B,
refer to the following table.
Voltage
Microwave Oven
Microwave Oven
and Microwave
and Microwave
Oven with Single
Oven with Single
Thermal Oven
Convection Oven
240 VAC
6230 W
6260 W
208 VAC
5239 W
5262 W
240 VAC
36.0 A
35.1 A
208 VAC
32.8 A
32.9 A
For power requirements for model KEHU309B, refer to the
following table.
Voltage
Microwave Oven and
Microwave Oven with Single
Convection Oven
240 VAC
7560 W
208 VAC
6246 W
240 VAC
40.5 A
208 VAC
37.7 A
A. Model/serial number plate
Models rated from 7.3 to 9.6 kW at 240 volts (5.4 to 7.4 kW
at 208 volts) require a separate 40-amp circuit. Models rated
at 4.8 kW and below at 240 volts (3.6 kW and below at
208 volts) require a separate 20-amp circuit.
Model KEHU309B requires a separate 50-amp circuit.
A circuit breaker is recommended.
Connect directly to the fused disconnect (or circuit breaker
box) through flexible, armored or nonmetallic sheathed,
copper cable (with grounding wire). See "Make Electrical
Connection"
section.
Flexible conduit from the oven should be connected directly
to the junction box.