Gardena 1892 Manuale dell'operatore - Pagina 8
Sfoglia online o scarica il pdf Manuale dell'operatore per Attrezzature per prato e giardino Gardena 1892. Gardena 1892 19. Water control
Anche per Gardena 1892: Manuale dell'operatore (18 pagine), Manuale dell'operatore (19 pagine)
GARDENA Automatic Water Distribu-
tor, Art. 1197 (optionally available)
v (Fig. O):
1 Menu: Water Distributor auto-
matic
This menu allows you to control up to
6 water lines with the Automatic Water Distributor.
This includes a necessary minimum pause of
5 minutes between the outlets and a minimum
watering duration of 30 seconds (display: 1 min).
This time ensures reliable switch-over to the next
outlet and makes sure that the schedules and
outlets are correctly linked (for details of the com-
missioning process, see the Operating Instructions
for the Water Distributor).
2 Select amount of active water lines
You can select any number between 2 and 6.
Seal any outlets on the Water Distributor that you
do not need with end caps and move the setting
lever to the "OFF" position.
3 Create schedules 1 ‒ 6:
When prompted to do so, enter watering schedules
L1 – L6 on the display. For this, use the standard
method for entering schedules based on the start
time, duration and frequency.
Note: Schedules are not allowed to overlap. If you
enter a schedule that overlaps with the next one,
the start time of the next watering operation will
be postponed and a pause of 5 minutes will be
inserted between the operations.
• Start times: Define the start times for the water
lines in chronological order. This makes it easier
to calculate and suggest the next possible start
time.
• Duration: The total watering duration for all outlets
– including the necessary pauses – must not
exceed 24 hours.
• Frequency: Different weekdays can be selected.
Note: To ensure correct switch-over and correct
linking of the schedules and outlets, any outlets
that are not scheduled to operate on a particular
day will still be activated for a period of 30 sec-
onds on the day concerned.
• Reduction in the number of outlets: If the number
of outlets is reduced, the superfluous channels
will be deleted. For example, if the number of
outlets is reduced from 5 to 3, the settings for
no. 4 and no. 5 will be deleted.
• Active (manual) watering: To activate a watering
operation manually, press
a minimum duration of 30 seconds and a pause
of at least 5 minutes must be observed.
4 Sensor per line (optional)
• If a soil moisture sensor is connected, you have
the option of activating / deactivating it for each
individual outlet. If the sensor is deactivated for
a particular schedule, watering will always take
place based on the schedule.
. Please note that
21