Gardena Classic 3500/4 Manuale di istruzioni per l'uso - Pagina 6

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Attrezzature per prato e giardino Gardena Classic 3500/4. Gardena Classic 3500/4 15. Garden pump
Anche per Gardena Classic 3500/4: Manuale dell'operatore (10 pagine), Manuale dell'operatore (11 pagine), Manuale di istruzioni per l'uso (14 pagine), Manuale di istruzioni per l'uso (10 pagine), Manuale di istruzioni per l'uso (7 pagine), Manuale dell'operatore (9 pagine), Manuale dell'operatore (10 pagine)

Gardena Classic 3500/4 Manuale di istruzioni per l'uso

6. Maintenance

Flush through Garden Pump:

7. Trouble-Shooting

Free the
impeller:
0
Problem
Pump runs, but the suction
action doesn't take place
The GARDENA Garden Pump is essentially maintenance-free.
The pump must be flushed through after discharging chlorinated
swimming pool water.
1. Pump through lukewarm water (max. 35 °C), possibly adding
a mild cleaning agent (e.g. detergent) until the pumped water
runs clear.
2. Remove residuals according to the waste disposal laws
applicable in your area.
DANGER! Electric shock!
Risk of injury due to electric shock.
v Disconnect Garden Pump from the mains before
trouble-shooting.
An impeller blocked by dirt can be freed again.
v Turn the impeller bolt
This will free the blocked impeller.
Possible Cause
Pump sucks in air at a joint.
Leaky or damaged suction
hose.
The pump was not filled with
the liquid to be pumped.
The liquid escapes over the
hose which is connected to
the delivery side during the
suction action.
Absolutely vacuum-resistant connection is achieved by using
GARDENA Suction Hoses (see point "8. Available accessories").
Leaky screw fitting
at the filler
6
cap
.
7
Air cannot escape, since delivery
side is closed or remaining water
is in the pressure hose.
using a screwdriver.
0
Remedy
v Seal connections on suction
side so are airtight.
v Check suction line for damage
and seal so is airtight.
v Fill the pump
(see "4. Operation").
1. Fill the pump again
(see "4. Operation").
2. When starting operation hold
the pressure hose approx.
1 m vertically above the
pump, until the suction
action has taken place.
v Check seal (replace if neces-
sary) and tighten connection
securely (do not use pliers).
v Open shut-off valves
(e. g. nozzle) in the delivery
line, empty the delivery hose
or disconnect it from the
pump during priming.
15