Fronius TransPocket 150 Manuale rapido - Pagina 2

Sfoglia online o scarica il pdf Manuale rapido per Sistema di saldatura Fronius TransPocket 150. Fronius TransPocket 150 2.
Anche per Fronius TransPocket 150: Manuale di avvio rapido (8 pagine), Procedura di aggiornamento (7 pagine), Riferimento rapido (2 pagine)

Fronius TransPocket 150 Manuale rapido
ACCESSING THE SETUP MENU
Setup menu
MMA welding
CHANGING WELDING PARAMETERS
Turn and press the adjusting dial to select and change parameters.
PARAMETERS FOR MMA WELDING
Starting current duration: 0.1 - 1.5 seconds |
0.5 seconds*
Anti-stick: On* / OFF
Start ramp: On* / OFF
Break voltage: 25 - 90 V | 45 V*
Factory setting
Level 2 Setup menu
WELDING PARAMETERS IN THE LEVEL 2 SETUP MENU
Software version
Automatic switch-off: 5 - 60 minutes / OFF*
Fuse: 230 V = 10 A, 13 A, 16 A* /
120 V = 15 A, 16 A, 20 A*
Operating time: hours, minutes, seconds
Welding time: hours, minutes, seconds
ACCESSING THE SETUP MENU
Setup menu
MMA welding
CHANGING WELDING PARAMETERS
Turn and press the adjusting dial to select and change parameters.
PARAMETERS FOR MMA WELDING
Starting current duration: 0.1 - 1.5 seconds |
0.5 seconds*
Anti-stick: On* / OFF
Start ramp: On* / OFF
Break voltage: 25 - 90 V | 45 V*
Factory setting
Level 2 Setup menu
WELDING PARAMETERS IN THE LEVEL 2 SETUP MENU
Software version
Automatic switch-off: 5 - 60 minutes / OFF*
Fuse: 230 V = 10 A, 13 A, 16 A* /
120 V = 15 A, 16 A, 20 A*
Operating time: hours, minutes, seconds
Welding time: hours, minutes, seconds
Setup menu
Cel electrodes
PARAMETERS FOR TIG WELDING
Operating mode: OFF / 2-step* / 4-step
Starting current: 1 - 200 % | 50 %*
Reduced current: 1 - 200 % | 50 %*
Final current: 1 - 100 % | 50%*
Gas post-flow time: 0.2 - 9.9* seconds
Comfort Stop sensitivity:
TP150 = OFF / 0.5 - 2.5 V | 1.6 V*
TP180 = OFF / 0.5 - 2.5 V | 1.5 V*
Break voltage: 12 - 22 V | 15 V*
Tacking function: OFF* / 0.1 - 5.0 seconds
Factory setting
Level 2 Setup menu
Setup menu
Cel electrodes
PARAMETERS FOR TIG WELDING
Operating mode: OFF / 2-step* / 4-step
Starting current: 1 - 200 % | 50 %*
Reduced current: 1 - 200 % | 50 %*
Final current: 1 - 100 % | 50%*
Gas post-flow time: 0.2 - 9.9* seconds
Comfort Stop sensitivity:
TP150 = OFF / 0.5 - 2.5 V | 1.6 V*
TP180 = OFF / 0.5 - 2.5 V | 1.5 V*
Break voltage: 12 - 22 V | 15 V*
Tacking function: OFF* / 0.1 - 5.0 seconds
Factory setting
Level 2 Setup menu
Setup menu
TIG
* factory setting
Setup menu
TIG
* factory setting