Gardena 9335-20 Manuale dell'operatore - Pagina 7

Sfoglia online o scarica il pdf Manuale dell'operatore per Soffiante Gardena 9335-20. Gardena 9335-20 10. Accu blower
Anche per Gardena 9335-20: Manuale di istruzioni per l'uso (16 pagine), Manuale di istruzioni per l'uso (18 pagine), Manuale di istruzioni per l'uso (17 pagine), Manuale di istruzioni per l'uso (17 pagine)

Gardena 9335-20 Manuale dell'operatore
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household
waste. It must be disposed of in line with local environmental
regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling
collection centre.
Disposal of the battery:
The GARDENA battery contains lithium-ion cells that should
not be disposed of with normal household waste at the end of
its life.
IMPORTANT!
v Dispose of the batteries through or via your municipal recycling
collection centre.
1. Discharge the lithium-ion cells completely (contact the GARDENA
Service).
2. Protect the contacts on the lithium-ion cells against short circuits.
3. Dispose of the lithium-ion cells properly.
6. MAINTENANCE
DANGER! Risk of injury!
Physical injury if the blower switches on unintentionally.
v Before maintenance, remove the battery
(see 3. INITIAL OPERATION).
Before each use:
Keep all nuts, bolts and screws tight to be sure the product is in a safe
working condition.
1. Be sure all parts are assembled properly.
2. Check to see whether fastening elements and components
(e. g. blower tube) have become loose, damaged or worn.
3. Contact your authorized service dealer for replacement of damaged
or worn parts.
4. ON / OFF Switch – Ensure switch functions properly by moving the
switch to the OFF position. Make sure motor stops; then restart motor
and continue.
After each use:
1. Inspect and clean unit and labels.
2. After each use, inspect complete unit for loose or damaged parts.
Clean the unit using a damp cloth.
3. Wipe off unit with a clean dry cloth.

7. TROUBLESHOOTING

DANGER! Risk of injury!
Physical injury if the blower switches on unintentionally.
v Remove the battery before troubleshooting
(see 3. INITIAL OPERATION).
Problem
Possible Cause
Blower does not function
Battery is flat.
Battery not pushed onto the
handle properly.
Switch in the OFF (0) position.
Blower vibrates abnormally
Mechanical failure.
Blower does not function.
Battery overload.
¥
Error-LED
on the battery
flashes [ Fig. I3 ]
Under voltage.
Battery temperature is out of
range.
Blower does not operate.
Battery error / battery defective. v Contact the GARDENA
¥
Error-LED
on the battery
illuminates [ Fig. I3 ]
Problem
Charging control lamp
on the charger does not
illuminate [ Fig. I2 ]
Charging control lamp
on the charger flashes red
[ Fig. I2 ]
The battery can no longer
be charged
Only an original GARDENA BLi-18 Replaceable Battery (Art. 9839) may be used.
This can be obtained from your GARDENA dealer or directly from GARDENA Service.
Li-ion
8. TECHNICAL DATA
Accu Blower
Blow speed (max.)
Weight (including battery)
Sound pressure level L
Uncertainty k
Sound power level L
measured/guaranteed
Uncertainty k
Hand/arm vibration a
Uncertainty k
Measuring process complying with:
sure. The vibration emission value can vary during actual use of the electric power tool.
System Battery BLi-18
Battery voltage
Battery capacity
Battery charging time
80 % / 100 % (approx.)
Battery Charger 18 V
Mains voltage
Mains frequency
Rated Power
Output voltage
Max. output current
9. ACCESSORIES
GARDENA Replacement
Battery BLi-18
GARDENA Battery Charger
18 V
Remedy
v Charge battery
10. SERVICE / WARRANTY
(see 3. INITIAL OPERATION).
v Push battery onto the handle
Service:
and make sure that the lock-
ing buttons snap in correctly.
Please contact the address on the back page.
v Slide switch to ON (I) position.
Warranty:
v Contact GARDENA Service.
In the event of a warranty claim, no charge is levied to you for the services
v Release the start levers.
provided.
Start again.
GARDENA Manufacturing GmbH offers a 2-year warranty for this product
(from the date of purchase) if the product has been used exclusively for
v Charge the battery.
private purposes. This manufacturer's warranty does not apply to used
v Use the battery in surround-
products purchased from a secondary market. This warranty includes all
ings where temperatures are
significant defects of the product that can be proved to be material or
between 0 °C and 40 °C.
manufacturing faults. This war ranty is fulfilled by supplying a fully functional
replacement product or by repairing the faulty product sent to us free
Service.
of charge; we reserve the right to choose between these options. This
service is subject to the following provisions:
Possible Cause
(Lc)
Battery charger or charging
cable are not connected
correctly.
(Lc)
Battery temperature is out of
range.
Battery is defective.
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.
Unit
Value (Art. 9335)
km/h
190
kg
1,8
68
1)
dB (A)
pA
3
pA
:
2)
WA
77 / 80
dB (A)
3
WA
< 2,5
1)
m/s
2
vhw
1,5
a
EN 60335-2-100
RL 2000/14/CE
1)
2)
NOTE: The stated vibration emission value has been measured according to
a standardized test procedure and can be used for comparison of one electric
power tool with another. It can also be used for preliminary evaluation of expo-
Unit
Value (Art. 9839)
V (DC)
18
Ah
2.6
h
3.5 / 5
Unit
Value (Art. 9825-00.630.00)
V (AC)
230
Hz
50
W
16
V (DC)
18
mA
600
Battery for additional duration or for replace-
ment.
Charger to charge the GARDENA Batteries
BLi-18.
Remedy
v Connect the battery charger
and charging cable correctly.
v Use the battery in surround-
ings where temperatures are
between 0 °C and 40 °C.
v Replace the battery
(Art. 9839).
Art. 9839
Art. 8833
11