For best results during vacuum use, operate your unit at high speed.
Move slowly back and forth over the material as you vacuum. Avoid forcing
the unit into a pile of debris as this can clog the unit.
Keep the vacuum tube about an inch above the ground for best results.
WARNING! If the unit becomes clogged, stop the unit and
unplug the extension cord. Wait until the impeller has
completely stopped turning, then remove the vacuum
tubes. Carefully reach into the vacuum opening and clear out the
clogged debris.
This will reduce possible personal injury from the impeller.
4. STORAGE
To put into storage:
Store unit unplugged, well out of the reach of children.
1. Stop unit and disconnect from the mains electricity supply.
2. Allow motor to cool before storing or transporting.
3. Store unit with all guards in place. Position unit so that any sharp object
cannot accidentally cause injury.
Extended storage:
Prepare unit for storage at the end of the season or if it will not be used for
30 days or more.
If your blower is to be stored for a period of time:
1. Stop unit and disconnect from the mains electricity supply.
2. Clean the entire unit before lengthy storage.
3. Open inlet cover and clean any dirt, grass, or debris that has collected.
Inspect the blower and all tubes. Close and make sure the cover is
latched.
4. Use a soft brush to clean air vents and air inlet of debris. Do not use
water.
5. Store your unit and extension cord in a well ventilated area and covered,
if possible, to prevent dust and dirt accumulation. Do not cover with
plastic. Plastic cannot breathe and may cause condensation and even-
tual rust or corrosion.
6. Check entire unit for loose screws. Replace any damaged, worn, or
broken parts.
7. Remove tube(s) for easier storage.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling collec-
tion centre.
5. MAINTENANCE
WARNING! Stop the unit and disconnect the plug from the
power source before making any adjustments, changing
accessories, or performing maintenance.
Such preventive safety measures reduce the risk of starting the power
tool accidentally.
BEFORE EACH USE
Check for loose fasteners and parts:
Keep all nuts, bolts and screws tight to be sure the product is in a safe
working condition. Be sure all parts are assembled properly.
• Inlet Cover
• Blower Tube
• Vacuum Tubes
• Collection Bag
Check for damaged or worn parts:
Contact your authorized service dealer for replacement of damaged or
worn parts.
• ON/OFF Switch – Ensure switch functions properly by moving the
switch to the OFF position. Make sure motor stops; then restart motor
and continue.
• Inlet Cover – Discontinue use of unit if inlet cover fails to latch properly or
if it is damaged in any way.
AFTER EACH USE
Inspect and clean unit and labels:
DANGER!
Electric shock!
Never clean the ventilation slit with a metal object.
• After each use, inspect complete unit for loose or damaged parts. Clean
the unit using a damp cloth.
• Wipe off unit with a clean dry cloth.
Clean collection bag:
IMPORTANT!
THE COLLECTION BAG MUST BE PROPERLY EMPTIED.
• You must properly empty and maintain the collection bag to avoid dete-
rioration and obstruction of air flow.
• Remove the collection bag from the unit and empty after each use. Do not
store bag without emptying the bag of all contents (grass, leaves, etc.).
• Wash the bag once a year. Remove the bag from the blower and turn
the bag inside out. Wash the bag with a water hose. Allow the bag to
hang and dry completely before you reuse the bag.
WARNING! If the unit becomes clogged, stop the unit and
unplug the extension cord. Wait until the impeller has
completely stopped turning, then remove the vacuum
tubes. Carefully reach into the vacuum opening and clear out the
clogged debris.
This will reduce possible personal injury from the impeller.
Removing an object from the air intake:
1. Remove the vacuum tubes.
2. Carefully reach into the vacuum opening and clear out the air intake
area. Clear all debris from impeller.
3. Inspect the impeller for cracks. If cracked or damaged, do not use the
unit. Have parts replaced by your authorized service dealer. Do not
attempt to replace them yourself.
6. TROUBLESHOOTING
WARNING! Always stop unit and unplug the extension cord
before performing all of the recommended remedies
below except remedies that require unit to be operating.
The motor must be stopped and the impeller blades no longer turning to
avoid serious injury from the rotating blades.
Problem
Possible Cause
Unit fails to operate
1. Switch in the OFF (0)
position.
2. Extension cord
disconnected.
3. Circuit breaker tripped,
or fuse blown.
4. Blower tube, elbow tube,
and/or vacuum tube not
installed correctly.
5. Collection bag is full.
6. Mechanical failure.
Unit vibrates abnormally
1. Mechanical failure.
Impeller will not
1. Debris in air intake area.
turn freely
2. Mechanical failure.
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.
Remedy
1. Slide switch to ON (I)
position.
2. Reconnect extension cord.
3. Reset circuit breaker or fuse.
4.Check tube installation.
5. Empty collection bag.
6. Contact your authorized
service dealer.
1. Contact your authorized
service dealer.
1. Clean unit. Remove any
debris.
2. Contact your authorized
service dealer.
11