AlienTek DP100 Manuale d'uso - Pagina 13

Sfoglia online o scarica il pdf Manuale d'uso per Generatore portatile AlienTek DP100. AlienTek DP100 18. Digital power

recalled separately, Users can set output parameters (1.8V, 3.3V, 5.0V, etc.) according to their own
needs. After setting, preset groups can be directly called out and used, and there is no need to set
voltage and current every time, which is convenient and quick.
⑥ Output voltage setting and constant current setting: Change the output voltage and
constant current value of the current preset group (only change and not save, and the initial value
is still the same after the DP100 is restarted).
⑦ System parameters: including overheat protection parameter setting (50~80℃), overpower
protection parameter setting (≤105.0W), backlight brightness level (0~4), buzzer volume level
(0~4), Rep setting(ON/OFF),Auto out setting(ON/OFF).
⑧ Status/On-Off column: There are three output modes: OFF, CV, CC; the working status
includes normal status NM, overvoltage protection status OVP, overcurrent protection status OCP,
overpower protection status OPP, overheat protection status OTP, undervoltage protection status
UVP, reverse connection protection state REP; Output indication includes three states: open, close,
and under-voltage lockout (when input voltage <4.8V).
Notes:
① After connecting to ATK-DP100, the control panel is automatically locked, and the device cannot be
operated from the control panel.
② If auto-save is selected, a large csv file will be generated on disk at high refresh rate.

5.2 Advanced function interface

5.2.1 Advanced function

The advanced function is convenient for users to output the setting data according to the
timing. The interface is shown in Figure 5.2.1:
① Sequence output: First set the output voltage, current and delay, select the serial number
range and cycle times.
User Manual
DP100 Digital Power User Manual
Figure 5.2.1 Advanced function Interface
11
High Performance Digital Power
www.alientek.com