Garmin GNS 530 Manuale di installazione - Pagina 3

Sfoglia online o scarica il pdf Manuale di installazione per Display avionico Garmin GNS 530. Garmin GNS 530 14. Supplement a21 to the airplane flight manual da 40 diamond com/nav/gps
Anche per Garmin GNS 530: Manuale del pilota (22 pagine), Manuale di istruzioni (6 pagine), Addendum al Manuale del Pilota (27 pagine), Addendum al Manuale del Pilota (4 pagine), Riferimento rapido (16 pagine), Opuscolo (1 pagine), Riferimento rapido (23 pagine), Addendum al Manuale del Pilota (22 pagine), Manuale (35 pagine)

Garmin GNS 530 Manuale di installazione
1.3

TECHNICAL SPECIFICATIONS

The conditions and tests required for TSO approval of this article are minimum performance standards. It
is the responsibility of those installing this article either on or within a specific type or class of aircraft to
determine that the aircraft installation conditions are within the TSO standards. TSO articles must have
separate approval for installation in an aircraft. The article may be installed only in compliance with 14
CFR part 43 or the applicable airworthiness requirements. For TSO compliance, see Appendix A.
1.3.1
Physical Characteristics
Bezel Height
Bezel Width
Rack Height (Dimple-to-dimple)
Rack Width
Depth Behind Panel with
Connectors (Measured from
face of aircraft panel to rear of
connector backshells)
GPS 500 Weight (Unit only)
GPS 500 Weight (Installed with
rack and connectors)
GNS 530 Weight (Unit only)
GNS 530 Weight (Installed with
rack and connectors)
1.3.2
General Specifications
Operating Temperature Range
Humidity
Altitude Range
Input Voltage Range
GPS 500 (011-00562-00, -10)
GNS 530 (011-00550-10, -30)
Input Voltage Range
GNS 530 (011-00550-00)
Input Voltage Range
GNS 530A (011-00835-00, -10)
Power Requirements
GPS 500
Power Requirements—P5001
(GNS 530 Main Connector)
Power Requirements—P5002
(COM Connector)
GNS 530 (011-00550-00)
GNS 530A (011-00835-00, -10)
Power Requirements—P5002
(COM Connector)
GNS 530 (011-00550-10)
Superflag Power Requirements
Software
Environmental Testing
Page 1-2
Rev S
4.58 in. (116 mm)
6.25 in. (159 mm)
4.60 in. (117 mm)
6.32 in. (161 mm)
11.00 in. (279 mm)
5.7 lbs. (2.59 kg)
7.2 lbs. (3.27 kg)
7.0 lbs. (3.18 kg)
8.7 lbs. (3.95 kg)
-20°C to +55°C. For more details see Environmental
Qualification Form.
95% non-condensing
-1,500 ft to 50,000 ft
11 to 33 Vdc
22 to 33 Vdc
28 Vdc
800 mA @ 27.5 Vdc (maximum)
1.6 A @ 13.8 Vdc (maximum)
1.8 A @ 27.5 Vdc (maximum)
3.6 A @ 13.75 Vdc (maximum)
15 mA @ 27.5 Vdc (not transmitting);
3.0 A @ 27.5 Vdc (transmitting)
15 mA @ 27.5 Vdc (not transmitting);
3.0 A @ 27.5 Vdc (transmitting)
15 mA @ 13.75 Vdc (not transmitting);
6.0 A @ 13.75 Vdc (transmitting)
500 mA max. Per superflag output @ 27.5 Vdc
1.0 A max. @ 27.5 Vdc on P5001 (Main Superflags).
1.0 A max. @ 27.5 Vdc on P5006 (VOR/LOC, G/S
Superflags).
RTCA DO-178B level C
RTCA DO-160C.
For more details see Environmental Qualification Forms.
500 SERIES INSTALLATION MANUAL
.
190-00181-02