Alert Text
CDI key stuck
CDI key disabled
Check unit cooling
COM has failed (530W
only)
COM is not responding
(530W only)
COM needs service
(530W only)
COM push-to-talk key
stuck (530W only)
COM remote transfer
key is stuck (530W
only)
COM transfer key stuck
(530W only)
COM transmitter power
has been reduced
(530W only)
Configuration error -
Config service req'd
500W Series
Instructions for Continued Airworthiness Bell 206B
Possible Cause
 The CDI key is stuck in the enabled
(or "pressed") state. Try pressing the
CDI key again to cycle its operation.
 "Ignore CDI key" has been selected on
the MAIN CDI/OBS CONFIG page.
 The 500W Series unit has detected
excessive display backlighting
temperature. The backlighting has
been automatically dimmed to reduce
the temperature.
 The unit has detected a failure in its
communications transceiver.
 Internal system-to-system
communication between the main
processor and the COM transceiver
has failed. Operational status of the
COM transceiver is unknown.
 The unit has detected a failure in its
communications transceiver. The
COM transceiver may still be usable.
 The external push-to-talk (PTT) switch
is stuck in the enabled (or "pressed")
state.
 Wiring is incorrect.
 The remote COM transfer switch is
stuck in the enabled (or "pressed")
state.
 The COM flip-flop key is stuck in the
enabled (or "pressed") state.
 The unit has detected excessive unit
temperature. The COM transceiver
transmit power has been automatically
reduced to compensate for the
condition.
 Insufficient voltage level
 The configuration information has
been lost or corrupted.
Solution
 Contact Garmin technical
support.
 Go to the MAIN CDI/OBS
CONFIG page and deselect
"Ignore CDI key"
 Check for adequate ventilation
or check cooling airflow. Refer
to Section 2.7 of the
Installation Manual.
 Contact Garmin technical
support.
 Contact Garmin technical
support. If the COM board is
still working, it will
automatically tune to 121.500
MHz. Transmit and receive
functions may still operate
regardless of the displayed
frequency.
 Contact Garmin technical
support
 Try pressing the PTT switch
again to cycle its operation.
 Check Wiring
 Try pressing the switch again
to cycle its operation.
 Verify the wiring is correct.
 If the message persists,
contact Garmin technical
support.
 Try pressing the switch again
to cycle its operation.
 If the message persists,
contact Garmin technical
support.
 Check for adequate ventilation
or check cooling airflow.
Refer to Section 2.7 of the
Installation Manual.
 Check the input voltage
 Reconfigure the unit
190-01226-03 Rev. 5