The burner is only partly
glowing
The burner makes a lot
of noise after ignition or
after several minutes
The burner do not work
at minimum position
Heater will not attain the
desired temperature
Declaration of conformity
We, Alke B.V., located in Scherpenzeel, The Netherlands, hereby declare that the Global series, marked
on their dataplates with CE and with CE approval/production supervision by Kiwa (number 0063) are in
compliance with the following EU legislation:
-
Directive on appliances burning gaseous fuels (GAD) 2009/142/EC (ex 90/396/EEC)
-
Regulation on appliances burning gaseous fuels (GAR) 2016/426/EU
-
Low Voltage Directive (LVD) 2014/35/EU (models with electric components)
-
EMC Directive (EMC) 2014/30/EU (models with electric components)
Scherpenzeel, 01-09-2017
Adri van Alphen
President
Version: Sept 2017
Wrong gas or pressure is used. Check data plate with the gas supply
Check if the injector or venturi are blocked or dirty
Check the injector and venture size with the table
Check if pipe sizes or gas hoses have sufficient capacity
Check the setting of the thermostat
Valve (35) dual injection model (Di) is blocked
Wrong gas is used. Check data plate with the gas supply
Check if the inner globe is broken or damaged so the flame burns
inside the venturi tube
A zoom noise of the EID2G is created by magnetic fields and lasts only
30 seconds. Not harmful. Temperature dependent. Turn the EID2G in
another position
Gas pressure is not correct. Check the gas pressure with the data plate
Wrong gas is used. Check data plate for the correct gas supply
Check the size of the venturi and injector with the table
Sensor or wire thermostat (T) is broken
Thermostat (T) valve adjusting mechanism is blocked
By-pass hole thermostat (T) or solenoid valve (S) is blocked
Injector (partly) blocked
Centre hole dual injector (Di) is blocked
Check if the thermocouple has the proper depth in the burner,
measured on the top plate (Global 5 = 25mm, Global 10 = 22 mm)
There is insufficient heat in the building for heat loss (i.e., not enough
brooders).
The thermostat (T) sensing bulb is incorrectly placed
The thermostat (T) is out of calibration or broken
The solenoid valve (S) is not functioning
One of the two holes of the dual injector (Di) is blocked
Injector partly blocked