alkitronic H Series Manuale di funzionamento e manutenzione - Pagina 13
Sfoglia online o scarica il pdf Manuale di funzionamento e manutenzione per Utensile elettrico alkitronic H Series. alkitronic H Series 16. Hydraulic torque wrench
Lubrication points (Fig. 5)
(without dismounting Torque
Wrench). First clean and dry the
components.
H-AX Hex Link
(1)
Apply grease onto both outer surfaces of drive plate,
(2)
both front surfaces and
(3)
both-sided slotted holes as well as drive pin.
H-AX Drive
(4)
Apply grease onto outer surfaces of piston rod front part
(5)
and slide surfaces of slider
1
2
3
4
H-AT Torque Wrench
(6)
Preparation:
remove shroud screws and shroud,
(7)
apply grease onto both inner surfaces of housing.
7
6
6
H-AX / H-AT
5
13
hydraulic torque wrenches
7.2
Storage
Always store the dry, clean alkitronic® Hydraulic
Torque Wrench in its transportation case or in any
lockable box. Moisture leads to oxidation on both
housing and interior parts. As a result malfunction
and further damages may occur.
For storage, make sure the hydraulic hoses are disconnected
and that the ends of the hose lines and the connecting compo-
nents (couplings/nipples) are plugged with protecting caps.
• Store the hydraulic hoses in a cool, dry, and dust-free loca-
tion.
• Avoid direct solar and UV radiation, ozonegenerat-
ing lighting (i.e. fluorescent sources of light, mercury
vapor lamps), and storage temperatures below -10°C.
7.3
Taking out of operation
If the alkitronic® Hydraulic Torque Wrench is stored
for a long time, store the cleaned tool in a closeable
and dry room, out of the reach of children. Moving
tool parts are to be protected against oxidation.
Additionally note item 7.2, Storage.
7.4
Maintenance intervals
The Torque Wrench must be submitted at least
once a year for inspection. After high strain/loads/
hours of operation, wear or leakage, calibration and
servicing must be carried out after shorter periods.
Lubrication - also see page 12, item 7.1.
8.
Technical Notes
To avoid faulty bolted joints or motor damage, observe the
following:
• Oil temperature must not exceed 65°C.
• Regularly check oil level and oil condition on pump reservoir.
• Regularly check the accuracy of the gauge with a testing
manometer.
9.
Appendix
- Trouble Shooting, page 14
- Technical Data, page 15
- Torque Chart (Attachment)
Materials and specifications are subject to change without notice.
©alkitechnik / GBA AT-H-AX /2/28-06-22-4Pdesign