1.

Safety instructions

1.1

Obligations of the operator

The user is obliged to read these operating and maintenance
instructions before carrying out any operation or service.
alkitronic® CL operations may only be performed by persons
who are familiar with the purpose, consequences and exact
execution.
The user must not be impaired in any way, such as through
drugs, alcohol and medication.
1.2

Intended use

alkitronic® CL are suitable for continuously rotating tightening
and loosening of heavy screw connections. Any other use,
e.g. as a stirring or drilling machine, can cause damage to the
device and the operator. The torque multipliers must not be
subjected to external mechanical forces that could lead to
deformation. Other types of use not listed here require the
approval of alki TECHNIK GmbH.
If you have questions about safety measures and areas of ap-
plication, your alkitronic® Partner will be happy to help you.
Incorrect operation, improper use, operation by
unqualified personnel can cause serious personal
injury and property damage.
The user is responsible to third parties in the work
area.
2.

Operation

Depending on the work environment and field of applica-
tion for the alkitronic® CL multiplier, local regulations for the
wearing of body protection (eg safety shoes, helmet, etc.)
may apply.
Failure to comply with such regulations can result
in serious bodily injury (e.g. crushing, head inju-
ries from flying metal parts). When operating the
alkitronic® CL wearing of hearing protection is
mandatory. In continuous operation, the handle
housing cools down greatly. Wearing gloves is
therefore recommended.
2.1

Commissioning

Depending on the field of applciation, standard nuts / con-
nectors, special torque transducers or adapters are required
for tightening and loosening screw connections (available as
accessories). The standard nuts / connectors are attached to
the output square and secured. Exchange see also Service,
section 3.1.
Before the compressed air is connected, the multiplier must
be prepared for the process:
Pneumatic Torque Multiplier
5
Conducting a security check for correct fit of the adapter
Check for possible damages of the DMAs or adapter
In case of damage, replace immediately - do not continue
working. Only use original alkitronic® accessories or spare
parts!
2.2

Preparing for use

4
5
alkitronic® DMA
Torque reaction absorber
• Place the alkitronic® CL multiplier on a flat surface
• Put support foot / DMA (1) on the gearing (4)
• Fix the standard nut / connector (2) / (3) to the square
shaft (5)
• Insert locking pin (7), secure with rubber ring (6)
or screw in the locking screw (8)
6
2
alkitronic®
STACO
1
Standard
nut
7
2
alkitronic® STACO
Standard nut
8
3
alkitronic® STABI
Standard connector