Type
PGN
Description
127250 Vessel heading
127488 Engine parameters: Rapid update
128259 Water speed
129025 Position: Rapid update
129029 GNSS position data
129283 Cross-track error
129284 Navigation data
129285 Navigation: Route/Waypoint information
130306 Wind data
130576 Small craft status

NMEA 0183 Information

When connected to optional NMEA 0183 compatible devices,
the autopilot uses the following NMEA 0183 sentences.
Type
Transmit
Receive

Error and Warning Messages

Error Message
Cause
ECU Voltage is Low
The pump supply voltage
has fallen below 10 Vdc
for longer than 6 seconds.
Autopilot is not
The autopilot is no longer
receiving navigation
receiving valid navigation
data. Autopilot placed
data while performing a
in Heading Hold.
Route To maneuver.
This message also
appears if navigation is
stopped on a chartplotter
before the autopilot is
disengaged.
Connection with
The helm control has lost
Autopilot Lost
connection with the CCU.
Lost Wind Data
The autopilot is no longer
(sailboat only)
receiving valid wind data.
Low GHC
Supply
The supply voltage level
Voltage
has fallen below the value
specified in the low
voltage alarm menu.
Error: ECU High
The pump supply voltage
Voltage
has risen above 33.5 Vdc.
Sentence
hdm
wpl
gga
grme
gsa
gsv
rmc
bod
bwc
dtm
gll
rmb
vhw
mwv
xte
Autopilot Action
• Alarm sounds for
5 seconds
• Continues in
normal operation
• Alarm sounds for
5 seconds
• Autopilot
transitions to
heading hold
N/A
• Alarm sounds for
5 seconds
• Autopilot
transitions to
heading hold
N/A
• Alarm sounds for
5 seconds
• The ECU shuts
down
Error Message
Cause
Error: ECU Voltage
The ECU voltage has
has Dropped Rapidly
dropped quickly below
7.0 Vdc.
Error: ECU High
The ECU temperature has
Temperature
risen above 100°C
(212°F ).
Error: Lost
Communication between
Communication
the CCU and the ECU has
Between ECU and
timed out.
CCU (when the
autopilot is engaged)

Registering Your Device

Help us better support you by completing our online registration
today. Keep the original sales receipt, or a photocopy, in a safe
place.
1
Go to
my.garmin.com/registration
2
Sign in to your Garmin account.

Contacting Garmin Support

• Go to
support.garmin.com
product manuals, frequently asked questions, videos, and
customer support.
• In the USA, call 913-397-8200 or 1-800-800-1020.
• In the UK, call 0808 238 0000.
• In Europe, call +44 (0) 870 850 1241.
© 2017 Garmin Ltd. or its subsidiaries
Garmin
®
and the Garmin logo are trademarks of Garmin Ltd. or its subsidiaries,
registered in the USA and other countries. Reactor
of Garmin Ltd. or its subsidiaries. These trademarks may not be used without the
express permission of Garmin.
NMEA
, NMEA 2000
, and the NMEA 2000 logo are trademarks of the National Marine
®
®
Electronics Association.
Autopilot Action
• Alarm sounds for
5 seconds
• The error is
cleared when the
ECU voltage
rises above
7.3 Vdc.
• Alarm sounds for
5 seconds
• The ECU shuts
down
• The helm control
beeps, and
autopilot
transitions to
standby.
.
for help and information, such as
and Shadow Drive
are trademarks
9