Fujitsu AG G09LVCA Series Manuale tecnico e di progettazione - Pagina 22

Sfoglia online o scarica il pdf Manuale tecnico e di progettazione per Condizionatore d'aria Fujitsu AG G09LVCA Series. Fujitsu AG G09LVCA Series 47. Floor type

Fujitsu AG G09LVCA Series Manuale tecnico e di progettazione
11.
EXTERNAL INPUT & OUTPUT
Connector
CN14
CN20
11-1.

EXTERNAL INPUT

CONTROL INPUT (Operation/Stop or Forced stop)
The air conditioner can be remotely operated by means of the following on-site work.
"Operation/Stop" mode or "Forced stop" mode can be selected with function setting of indoor unit.
Unit operation is started at the following contents by adding the contact input of a commercial ON/OFF switch to a
connector on the external control PC board and turning it ON.
Unit operation
Operation mode
Set temperature
Airflow mode
Up-down air direction (swing)
Left-right air direction (swing)
Circuit diagram example
Indoor unit
control PC board
Connector
1
3
*: Make the distance from the PC board to the connected unit within 10 m.
When function setting is "Operation/Stop" mode
ON
Input signal
OFF
Operation
Indoor unit
Stop
When function setting is in "Forced stop" mode
ON
Input signal
OFF
Forced stop
Command
Normal
Operation
Indoor unit
Stop
Remote controller
INPUT
Control input
-
Operation status output
Initial setting after power is ON
Auto changeover
24 °C
AUTO
Standard air direction (swing OFF)
Standard air direction (swing OFF)
Connected unit
Ex.) Switch
10 m*
Signal
Field supply
ON
- (01 - 19) -
OUTPUT
-
See external input/output
settings for details.
Starting mode other than initial setting
Mode at previous operation
Temperature at previous operation
Mode at previous operation
Air direction at previous operation
Air direction at previous operation
Contact capacity : DC 24 V or more, 10 mA or more.
ON
ON
Remote control
operation invalidity
REMARKS