AEG 25742 GM Istruzioni per l'uso e l'installazione - Pagina 16

Sfoglia online o scarica il pdf Istruzioni per l'uso e l'installazione per Piano cottura AEG 25742 GM. AEG 25742 GM 20. Aeg cooktop user manual

Replacing the power supply lead
If the lead has to be replaced, only HO5RR-F or HO5RN-F type cables suitable for
the load and the operating temperature must be used.In addition, the yellow/green
earth wire must be about 2 cm longer than the live and neutral wires.
In all cases, the power supply lead must be positioned so that it does not reach a
temperature 50 C above the room temperature in any point.
One example of an ideal route is shown in the illustration.The cable is guided by
means of band clamps fixed to the side of the cabinet, in order to avoid any contact
with the appliance underneath the hob.

Adapting to the different types of gas

Changing the nozzles
1) Remove the pan stands
2) Remove the burner caps and flame caps from the
burners.
3) Use a size 7 socket wrench to unscrew and remove
the nozzles, replacing them with those corresponding
to the type of gas to be used (see table).
4) Reassemble the parts, reversing the operations
described above.
5) Then replace the setting data plate (close to the
mains gas connection) with the one for the new type
of gas (it is in the bag of nozzles provided).
If the pressure of the gas used is different from that specified (or variable), a suitable
piped gas pressure regulator complying with the standard must be installed on the
supply pipeline.
Setting the minimum level
1) Light the burner as already described.
2) Turn the tap to the minimum flame position.
3) Remove the control knobs.
4) Use a thin straight screwdriver to turn the by-pass pin located
next to the tap rod (see fig. A).If you are converting from natural
gas to LPG, turn the by-pass pin fully clockwise.
The result should be a small, homogeneous flame which is
uniform around the entire burner ring.
5) Finally, check that the burner does not go out when the tap is
turned quickly from the maximum to the minimum position.
16
A