2N Lift1 Compact Manuale breve - Pagina 11

Sfoglia online o scarica il pdf Manuale breve per Sistema interfonico 2N Lift1 Compact. 2N Lift1 Compact 12. For lifts
Anche per 2N Lift1 Compact: Manuale breve (12 pagine)

2N Lift1 Compact Manuale breve
992 – Rescue
password

Technical parameters

Electric Parameters

Parameter
Minimum line current
Minimum line voltage
Off-hook DC voltage drop
On-hook resistance
Off-hook impedance
Return loss
Bandwidth
Ringing impedance
Ringing detector sensitivity
Pulse dialling
DTMF dialling level
Overvoltage protection – between
A, B

Other Parameters

Compact model dimensions
Working temperature range
Note
Lift1 is certified for connection to a wired PSTN line according to the ES 023 021 standard
requirements.
The product does not contain components harmful to the environment. When the product's service
life is exhausted, dispose of it in accordance with the applicable legal regulations.
EC Declaration of Conformity
Hereby, 2N TELEKOMUNIKACE a.s., declares that the product
requirements and other relevant provisions of Directive Radio Equipment and Telecommunications Terminal
Equipment Directive (R&TTE) 1999/5/EC. Declaration of conformity you can find on our website www.2n.cz.
up to 16
empty
digits: 0–9
Value
15 mA
22 V
< 8 V
< 16 V
>1 MΩ
220 Ω + 820 Ω paral.
115 nF
> 14 dB
300 až 3500 Hz
> 2 kΩ
C = 0,47 μF
10 až 20 V
40 / 60 ms
-9,0 +2,0/-2,5 dB and
-11,0 dB +2,5/-2,0 dB
1000 V
100 x 185 x 23 mm
-20 to +70 ˚C
Set the rescue terminating password.
Condition
off-hook
on-hook
I = 25 mA
I = 50 mA
U = 25..100 V
15 to 60 mA
15 to 60 mA
15 to 60 mA
25 to 50 Hz
25 to 50 Hz
15 to 60 mA
8 / 20 μs
®
2N
Lift1
is in compliance with the essential
10