L i f e B o o k C S e r i e s B I O S
Table 17: Fields, Options and Defaults for the Power Menu
Menu field
Options
Suspend Mode:
Suspend
n
Save to Disk*
n
*Note that Save to
Disk is applicable
to Windows 98
operating system
only)
Auto Save
Off
n
to Disk:
After 1 Hour
n
Resume On
Off
n
Modem Ring:
On
n
Resume On Time:
Off
n
On
n
Resume Time:
00:00:00 to
n
23:59:59
Advanced
–—
Features:
Factory Installed Values for Power Saving Profiles
Customized:
Maximum Power Savings:
Maximum Performance:
Disabled:
Sample Customized Profile: (To get even better battery life keep
the display and volume settings as low as possible and use the
sample customized profile.)
30
Default
Description
[Suspend]
Sets the state of suspension used. If you choose Suspend, operation
will be suspended. Power will still be supplied to system memory,
but everything else will be powered down or will enter a very low
power state. If you choose Save-to-Disk, your notebook will save all
of system memory and operating parameters to the hard drive
before turning your notebook to the pseudo-off condition.
[Off]
When set to After 1 Hour, your notebook will automatically
save all of system memory and the operating parameters to the
hard drive, and go to the pseudo-off if you leave your notebook in
Suspend mode for an hour.
[Off]
Sets whether or not to Resume from a suspension state when a
message is received by telephone line. This feature will not operate
if the Save-to-Disk mode is enabled. This feature applies to internal
and external modems.
[Off]
Sets whether or not to resume from a suspension state at a
designated time. This feature is available from either the Suspend
mode or the Save-to-Disk mode.
[00:00:00]
Sets the designated time, on a 24-hour clock, when the notebook
is to automatically resume operation from the Suspend state.
The format of the clock setting is hours:minutes:seconds. Each
segment of the time is set separately, either by incrementing or by
typing in the numbers. You move between the segments with the
[Tab] key or the [Shift]+[Tab] keys. This only applies when Resume
on Time is set to On.
–—
When selected, opens the Advanced Features submenu which
allows setting additional power saving parameters.
Hard Disk
Timeout
Off
30 Seconds
Off
Off
2 Minutes
Standby
Auto Suspend
Timeout
4 Minutes
15 Minutes
1 Minute
5 Minutes
Off
15 Minutes
Off
Off
1 Minute
5 Minutes
Timeout