3 Exchange procedure

This chapter explains how we can exchange to a spare part.

3.1 Caution when exchanging

1.
Please use the antistatic wristband when exchanging and use antistatic mat when you put this product temporary on
somewhere else.
2.
Redundancy configuration such as using multiple switches and teaming configuration is needed when exchanging this
product without stopping network. Please check configuration and consult with system administrator when you
exchange this product.
3.
LAN port should be disabled from server blade side when exchanging switchblade if possible. LAN port on Server Blade
will link-up automatically when installing it in a chassis. Therefore, the ports become active before configuration
restore is completed when Active-Active teaming or Active-Standby teaming with Failback enable are configured.
4.
We recommend to use latest version Firmware for all switch blades in the system though the products can be used with
several firmware version mixed environment as its spec.

3.2 Exchange Procedure example

This section explains the example exchange procedure.
Change the configuration such as remote notification/alarm service in your system to prevent the system from sending
alert if needed.
Check the connecting cable and modules location of the switch.
Take the defect switchblade information.
show△tech-support command can take the almost logs.
(If it cannot be taken due to power supply defects or something, please go forward without taking logs.)
#show△tech-support
Check the firmware version and active firmware mode (Switch/IBP/EHM) of the target one.
Take the configuration backup file when you do not have it.
(If you cannot take the configuration backup and do not have the file, you have to configure all of them manually.)
Check which config file(config1 or config2) is used by show△system△information before backup. (Refer to Chapter 2.
to know how we can backup)
Remove the target switchblade
Remove all the cables and modules from the target switchblade. Then, remove that switchblade from the chassis.
There are release latch on switchblade (green one.). Slide it to the right side and open it. Then pull out the switchblade
to remove from the chassis.
Install the spare part.
Refer to Chapter 2 to know how to install the Connection Blade.
Note: Don't connect the cables before configuration restore is finished.
Update Firmware.
Refer to Chapter 2 to know how to update the Firmware
Configure Firmware active mode and IP address.
Refer to Chapter 2 to know how to configure them.
Restore the configuration.(Refer to Chapter 2 to know how to do it.)