Fujitsu PRIMERGY CX400 M1 Configuratore di sistema e manuale di informazione sugli ordini - Pagina 25
Sfoglia online o scarica il pdf Configuratore di sistema e manuale di informazione sugli ordini per Server Fujitsu PRIMERGY CX400 M1. Fujitsu PRIMERGY CX400 M1 33.
K2
CX25y0 M2
VIII
Section
2.5" SAS / SATA / PCIe Hard disk drives / SATADOM
Advanced Thermal Design
refer to ATD with S26361-F3776-E240
CPU type
Ambient
temp
w/o ATD option
35℃
<= 145W
30℃
160W
w/ ATD option
135/145/160W
40℃
(Liquid cooling only)
135W
40℃
40℃
<=120W
SATA Disk Drive 2.5"
HDD SATA 6Gb/s 2.5" with hot plug/hot replace tray
500GB 7.2krpm, 64MB Cache, 512n
1TB 7.2krpm,64MB Cache, 512n
1TB 7.2krpm, 128MB Cache, 512e
2TB 7.2krpm,128MB Cache, 512e
max. 2/6x per server node
Enterprise Solid State Disk, 10DWPD class
SSD SATA 6Gb/s 2.5" with hot plug/hot replace tray
200GB, write-intensive
400GB, write-intensive
800GB, write-intensive
1.2TB, write-intensive
max. 2/6 per server node
Enterprise Solid State Disk, 3DWPD over 5 years
SSD SATA 6Gb/s 2.5" with hot plug/hot replace tray
120GB, for read/write workload (mixed-use)
240GB, for read/write workload (mixed-use)
480GB for read/write workload (mixed-use)
960GB, for read/write workload (mixed-use)
1.92TB, for read/write workload (mixed-use)
max. 2/6 per server node
SAS Disk Drive 2.5"
HDD SAS 12Gb/s 2.5" with hot plug/hot replace tray
1TB 7.2krpm, 512n Sektor Size, 128MB Cache
2TB 7.2krpm, 512n Sektor Size, 128MB Cache
300GB 10krpm, 512n Sektor Size, 128MB Cache
600GB 10krpm, 512n Sektor Size, 128MB Cache
900GB 10krpm, 512n Sektor Size, 128MB Cache
1.2TB 10krpm, 512n Sektor Size, 128MB Cache
600GB 10krpm, 512e Sektor Size, 128MB Cache
900GB 10krpm, 512e Sektor Size, 128MB Cache
1.2TB 10krpm, 512e Sektor Size, 128MB Cache
1.8TB 10krpm, 512e Sektor Size, 128MB Cache
300GB 15krpm, 512n Sektor Size, 128MB Cache
300GB 15krpm, 512n Sektor Size, 128MB Cache
600GB 15krpm, 512n Sektor Size, 128MB Cache
max. 2 / 6 per server node
SSD SAS 12Gb/s 2.5" with hot plug/hot replace tray
400GB, Enterprise Performance
800GB, Enterprise Performance
400GB, Enterprise Performance
800GB, Enterprise Performance
1.6TB, Enterprise Performance
max. 2/6x per server node
SSD SAS 12Gb/s 2.5" with hot plug/hot replace tray
480GB, for read/write workload (mixed-use)
960GB, for read/write workload (mixed-use)
1.92TB, for read/write workload (mixed-use)
3.84TB, for read/write workload (mixed-use)
max. 2/6x per server node
SSD SAS 12Gb/s 2.5" with hot plug/hot replace tray
480GB, read intensive
960GB, read intensive
1.92TB, read intensive
3.84TB, read intensive
max. 2/6x per server node
PCIe Solid State Disk, Mainstream Endurance*
PCIe SSD only valid with two CPUs configuration
SSD PCIe
Gen3 2.5" with hot plug/hot replace tray
800GB
2x
1.6TB
2.0TB
max. 2 per server node w/ Type B drive bay option
L
front
PCIe slots
HDD
Air cooled Liquid cooled
6
2
1
0
2
1
6
-
1
2
2
1
6
2
1
S26361-F3895-E500
S26361-F3895-E100
S26361-F3936-E100
S26361-F3936-E200
S26361-F5592-E200
S26361-F5592-E400
S26361-F5592-E800
S26361-F5592-E120
S26361-F5588-E120
S26361-F5588-E240
S26361-F5588-E480
S26361-F5588-E960
S26361-F5588-E192
SAS Disk Drive 2.5"
S26361-F5600-E100
S26361-F5600-E200
S26361-F5550-E130
S26361-F5550-E160
S26361-F5550-E190
S26361-F5550-E112
S26361-F5543-E160
S26361-F5543-E190
S26361-F5543-E112
S26361-F5543-E118
S26361-F5531-E530
S26361-F5531-E545
S26361-F5531-E560
Enterprise Solid State Disk, Mainstream Endurance*
S26361-F5298-E400
S26361-F5298-E800
S26361-F5608-E400
S26361-F5608-E800
S26361-F5608-E160
S26361-F5614-E480
S26361-F5614-E960
S26361-F5614-E192
S26361-F5614-E384
S26361-F5617-E480
S26361-F5617-E960
S26361-F5617-E192
S26361-F5617-E384
S26361-F5534-E800
S26361-F5534-E161
S26361-F5534-E201
Fujitsu Technology Solutions x86 PRIMERGY Server
System configurator and order-information guide
PRIMERGY CX400 M1
ATD refer to S26361-F3776-E240
(Advanced Thermal Design)
CX25y0 M2
Endurance
10DWPD over 5y
CX25y0 M2
Endurance
3DWPD over 5y
Liquid Cooling is not possible
Liquid Cooling is not possible
*) SSD Mainstream Endurance
10DWPD over 5y
SSD Interface: SAS12Gb/s and SAS 6Gb/s.
For 12G support is an SAS 12G controller required
Endurance
3DWPD over 5y
Endurance
1DWPD over 5y
*) SSD Mainstream Endurance
xxDWPD over 5y
Status 2016-10-31
SATA
SATA
SAS
PCIe
25 of 33