8. Update the firmware by using the flashupdate(8) command.
Caution – flashupdate(8) will update one bank, reset the XSCF and commence
update of the second bank. Verify that the current and reserve banks are both
updated. If both banks indicate XCP revision 1060, proceed to the next step.
XSCF> flashupdate -c update -m xcp -s version
Specify the XCP version to be updated. In this examples, it's 1060.
9. Confirm completion of the update.
XSCF> showlogs event
Confirm no abnormality happens while updating.
10. Confirm that both the current and reserve banks of XSCFU#0 display the updated
XCP versions.
XSCF> version -c xcp
XSCF#0 (Active)
XCP0 (Reserve): 1060
XCP1 (Current): 1060
If the Current and Reserve banks on XSCF#0 do not indicate XCP revision 1060,
contact a certified service engineer.
11. Confirm no abnormality occurred by using showlogs error -v and
showstatus(8) commands.
XSCF> showlogs error -v
XSCF> showstatus
If you encounter any hardware abnormality of the XSCF, contact a certified service
engineer..
12. Power on all domains.
XSCF> poweron -a
32
SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1060 • February 2008